NE40E V800R010C10SPC500 Installation Guide

This is NE40E V800R010C10SPC500 Installation Guide
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Power-on Check

Power-on Check

Power-on Check Flowchart

  • Before a power-on check, ensure that the 12 circuit breakers are set to Off and the input voltage is within the correct range.
  • The voltage range of AC power distribution is from 180 V AC to 264 V AC (single-phase) or from 304 V AC to 457 V AC (three-phase).

Figure 15-8 DACS power switch

Figure 15-9 Power-on check flowchart

Indicators

Module/Board

Indicator

Color

Description

AC/AC Power Module

RUN/ALM

green/red

  • If the indicator blinks red once every 250 ms (4 Hz), a hardware fault occurs, and the communication is abnormal.
  • If the indicator blinks red once every 2 seconds (0.5 Hz), a hardware fault occurs, but the communication is normal.
  • If the indicator blinks green once every 250 ms (4 Hz), no hardware fault occurs, but the communication is abnormal.
  • If the indicator blinks green once every 2 seconds (0.5 Hz), no hardware fault occurs, and the communication is normal.

INPUTA

green

  • If the indicator is steady on, channel A supplies power.
  • If the indicator is off, channel A does not supply power.

INPUTB

green

  • If the indicator is steady on, channel B supplies power.
  • If the indicator is off, channel B does not supply power.

DMU

RUN

green

  • If the indicator blinks once every 2 seconds (0.5 Hz), the communication between the DMU and the PMU is normal.
  • If the indicator blinks once every 250 ms (4 Hz), the communication between the DMU and the PMU is abnormal.

ALM

red

  • If the indicator is steady on, a DMU hardware fault occurs.
  • If the indicator is off, the DMU is running properly.