Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Egress of a Static Bidirectional Co-routed CR-LSP

Configuring the Egress of a Static Bidirectional Co-routed CR-LSP

The egress of a static bidirectional co-routed CR-LSP needs to be manually specified.

Context

Perform the following steps on the egress of a static bidirectional co-routed CR-LSP:

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run bidirectionalstatic-cr-lsp egress tunnel-name

    A static bidirectional co-routed LSP is created, and the static bidirectional CR-LSP view is displayed.

    The tunnel-name value must be the name of an established tunnel.

  3. Run forward in-label in-label-value [ lsrid ingress-lsr-id tunnel-id ingress-tunnel-id ]

    A forward CR-LSP is configured on the egress.

    If lsrid ingress-lsr-id tunnel-id ingress-tunnel-id is specified in this command, the system checks whether the tunnel destination IP address on the egress and the specified value of ingress-lsr-id are consistent. If the specified value of ingress-lsr-id is different from the tunnel destination IP address on the egress, the tunnel cannot go Up. As a result, the forward and reverse CR-LSPs configured on the egress cannot go Up.

  4. Run backward { nexthop next-hop-address | outgoing-interface interface-type interface-number } * out-label out-label-value [ bandwidth ct0 bandwidth ]

    A reverse CR-LSP is configured on the egress.

    The bandwidth parameter specifies the reserved bandwidth for a reverse CR-LSP. The bandwidth value cannot be higher than the maximum reservable link bandwidth. If the specified bandwidth is higher than the maximum reservable link bandwidth, the forward CR-LSP cannot go Up.

  5. (Optional) Run description text

    A description is configured for the static bidirectional co-routed CR-LSP.

  6. Run commit

    The configuration is committed.