Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring a Hello Session Between RSVP GR Nodes

(Optional) Configuring a Hello Session Between RSVP GR Nodes

If TE FRR is deployed, a Hello session must be established between a PLR and an MP. A Hello session must be manually established if it cannot be automatically established between RSVP neighboring nodes.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run mpls

    The MPLS view is displayed.

  3. Run mpls rsvp-te

    RSVP-TE is enabled.

  4. Run mpls rsvp-te hello

    The RSVP Hello extension is enabled on the local node.

  5. Run mpls rsvp-te hello nodeid-session ip-address

    A Hello session is established between two RSVP neighboring nodes.

    The ip-address parameter specifies the LSR ID of an RSVP neighboring node.

  6. Run commit

    The configurations are committed.