Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling BFD Globally

Enabling BFD Globally

To configure dynamic BFD for CR-LSP, enable BFD globally on the ingress node and the egress node of a tunnel.

Context

Perform the following steps on the ingress and the egress of a TE tunnel:

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run bfd

    BFD is enabled globally.

  3. Run commit

    The configuration is committed.