Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Deleting an Automatic Bypass Tunnel and Re-establishing a New One

Deleting an Automatic Bypass Tunnel and Re-establishing a New One

If MPLS TE Auto FRR is enabled, a command is used to instruct a node to tear down an automatic bypass tunnel and reestablish a new one.

Procedure

  1. Run the reset mpls te auto-frr { lsp-id ingress-lsrid tunnel-id | name bypass-tunnel-name } command to tear down an automatic bypass tunnel and re-establish a new one.
Translation
Download