Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Hop Limit for a CR-LSP

Setting the Hop Limit for a CR-LSP

The hop limit set on an ingress is the maximum number of hops on a path along which a CR-LSP is to be established. The hop limit is a constraint used during path selection.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface tunnel tunnel-number

    The view of the MPLS TE tunnel interface is displayed.

  3. Run mpls te hop-limit hop-limit-value [ best-effort | secondary ]

    The hop limit of a CR-LSP is set.

  4. Run commit

    The configuration is committed.