Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking Security Risks

Checking Security Risks

Run the display security risk command to check security risks in the system. Then clear the security risks as prompted.

Context

Protocols have different security performances, and some protocols may have security risks. Run the display security risk command to identify security risks in the system. Then clear the security risks according to the repair action in the command output. For example, if SNMPv1 is configured, the display security risk command output will prompt for the use of SNMPv3.

Procedure

  1. Run display security risk [ feature feature-name ] [ level { high | medium | low } ]

    Security risks in the system and suggested solutions are displayed.
    NOTE:

    The security risks that are displayed vary with user levels. The system administrators can view all security risks in the system. Other users can only view the security risks whose level is lower than or equal to their levels.

Example

Run the display security risk command to view security risks in the system.

<HUAWEI> display security risk
Risk level       : high    
Feature name     : SNMP    
Risk information : SNMP V1/V2c is enabled
Repair action    : Disable SNMP V1/V2c and enable SNMP V3 only
 
Risk level       : medium  
Feature name     : CFM     
Risk information : Configurations are automatically backed up to the server by means of FTP/TFTP.
Repair action    : Use SFTP. 
            
Risk Level       : medium 
Feature Name     : FTPS 
Risk Information : FTP is not a secure protocol. 
Repair Action    : It is recommended to use SFTP. 