Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Information Filtering Function

Configuring the Information Filtering Function

To reduce redundant and unnecessary information on the device, configure the information filtering function.

Usage Scenario

Some services, such as ARP, generate a large amount of information within a short period of time. The information filtering function can be used to filter out redundant and unnecessary information on the device.

Pre-configuration Tasks

Before enabling the information filtering function, ensure that the device is powered on correctly and the self-test is successful.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run either of the following command to configure the information filtering function.

    • To filter out a specified log or trap, run the info-center filter-id { filter-id | bymodule-alias modname alias } command.

      The specified log or trap is not generated or output to any direction.

    • To enable statistics collection of consecutive repeated logs, run the info-center statistic-suppress enable command.

      If this function is enabled, only one of the repeated logs will be recorded.

    NOTE:
    Consecutive repeated logs have the same log ID and parameters, and no other logs exist between them.

  3. Run commit

    The configuration is committed.

Checking the Configurations

  • Run the display logbuffer command to check whether the log filtering function is effective.

    If the protocol status of the interface alternates between Up and Down after the info-center filter-id bymodule-alias modname alias command is run to filter out the alias log of the modname module, the log information cannot be displayed after the display logbuffer command is run.

<HUAWEI> display logbuffer
Sep 17 2011 15:41:48 HUAWEI %%01INFO/4/RST_LOGB(l)[2]:When deciding whether to reset the logbuffer, the user chose Y.