NE20E-S2 V800R010C10SPC500 Configuration Guide - System Management 01

This is NE20E-S2 V800R010C10SPC500 Configuration Guide - System Management
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling/Disabling a SAID Node

Enabling/Disabling a SAID Node

This section describes how to enable or disable a system of active immunization and diagnosis (SAID) node using commands.

Context

The diagnosis and recovery durations of a single SAID node must not exceed 10 and 30 minutes, respectively. If either duration is exceeded, the SAID node is disabled by default. When a SAID node is processing a large number of services, the processing efficiency of other SAID nodes may be reduced because of performance insufficiency. To guarantee the processing efficiency, you can run the set said-node command to disable this node.

If the node is not in the detecting state after being disabled, it automatically returns to the detecting state upon completion of the operation in the current phase. When the next SAID task is started to perform detection, the system detects that the SAID node is disabled and therefore skips it.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run set said-node { all | said-name [ slot slot-id ] } disable

    The SAID node is disabled.

    This command is supported only on the Admin-VS.

Checking the Configurations

After enabling/disabling a SAID node, check the configurations.

  • Run the display said-node status command to check the status of the SAID node.

    # Run the display said-node status [ slot slot-id ] brief command to check the status of the SAID node on the board in a specified slot. For example:

    <HUAWEI> display said-node status slot 1 brief
    -----------------------------------------------------------------------------   
    SAID-ID    NAME            TYPE        CYCLE(s)    STATUS          OPERATE      
    -----------------------------------------------------------------------------   
    2          PING            common      300         detecting       Disable      
    ----------------------------------------------------------------------------- 