NE20E-S2 V800R010C10SPC500 Feature Description - System Monitor 01

This is NE20E-S2 V800R010C10SPC500 Feature Description - System Monitor
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CE Ping

CE Ping

Background

On an MPLS network, a PE can send a CE Ping packet to a CE in a specified BD to check reachability to the CE. If the PE can receive a response packet from the CE, the PE determines that the CE is reachable.

Usage Scenario

  • In a VSI scenario

    In a traditional Ethernet service access model, VLAN services can be carried on VSIs on a VPLS network. A PE on the VPLS network sends a CE Ping packet to check CE reachability.

    CE ping is a tool that a PE on a VPLS network uses to monitor whether it can initiate an ARP request to reach a connected CE.

    Figure 5-9 illustrates a CE ping network in which CE1 and CE3 are directly connected to the VPLS network. The CE ping process is as follows:

    1. PE1 pings a CE (CE3 in this example) and sends ping packets destined for CE3's IP address. Because PE1 does not know the PE to which CE3 is connected, PE1 broadcasts an ARP request within the VPLS network to request the MAC address corresponding to the IP address of CE3.
    2. All CEs receive the ARP request messages. When CE3 discovers that the ARP request is destined for itself, it sends an ARP reply. When other CEs receive the ARP request, they discard the request.
    3. After PE1 receives the ARP reply from CE3, PE1 determines that it can reach CE3.

    Figure 5-9 Typical CE ping networking in a traditional Ethernet service access model

    In an EVC model, CE ping can also be used to check link reachability between a PE and a CE in a specified BD. The implementation process is similar to that in a traditional Ethernet service access model. For details about EVCs, see EVC.