Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling the Optical Module Alarm Threshold Standardization Function

Enabling the Optical Module Alarm Threshold Standardization Function

You can enable the alarm standardization function for an optical module to prevent the optical module from reporting alarms when its optical power exceeds the threshold.

Context

Enabling alarm threshold standardization implements optical power-related alarm threshold standardization and changes the mode of obtaining thresholds for sending and receiving optical power. If the optical-module threshold-standardization enable command is not run, thresholds are calculated based on data read from the optical module registers, which is the default mode of obtaining a threshold. If the optical-module threshold-standardization enable command is run, optical power thresholds use a standardized value that is calculated based on the optical module transmission distance and bandwidth.

NOTE:

The device has two types of optical module power alarms: warning and alarm. A warning is reported when the difference between the actual power and vendor-defined threshold is not great. It can also be considered as a precaution. Some optical modules can continue working properly when the actual optical power is at the warning level. You can disable the alarm function for these optical modules to prevent these optical modules from frequently reporting warnings by executing the following command.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run optical-module alarm-threshold standardization enable

    The alarm threshold standardization function is enabled for the optical module.