Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring Automatic Board Power Off Under High Temperature

(Optional) Configuring Automatic Board Power Off Under High Temperature

This section describes how to configure automatic board power off under high temperature, protecting boards from high temperature.

Context

The high-temperature working environment reduces the board lifespan. You can run the display temperature command to view the temperature alarm thresholds on each board. The alarm levels are minor, major, and fatal. When the board temperature is higher than a specific threshold, the corresponding level of alarm occurs. When the temperature is 5°C below the alarm threshold, the alarm is cleared. After this function is enabled, a board powers off automatically when temperatures of three or more monitoring nodes on the board are 5°C above the fatal high temperature alarm threshold.

This configuration process is supported only on the Admin-VS.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run high-temperature power-off enable

    Automatic board power off under high temperature is enabled.

Example

Run the display temperature command to check temperature information.