NE40E-M2 V800R010C10SPC500 Configuration Guide - System Management 01

This is NE40E-M2 V800R010C10SPC500 Configuration Guide - System Management
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the Configuration of Basic NTP Functions

Verifying the Configuration of Basic NTP Functions

After configuring basic NTP functions, check details about the configured and dynamic NTP sessions and the status of the NTP service.

Prerequisites

Basic NTP functions have been configured.

Procedure

  • Run the display ntp-service sessions command to check the details about the configured and the dynamic NTP sessions.
  • Run the display ntp-service trace command to trace the path of reference clock source from the local device.
  • Run the display ntp-service bd-status command to check the status of each board on a Router.

Example

Run the display ntp-service sessions command to view the details about the configured and the dynamic NTP sessions.

<HUAWEI> display ntp-service sessions
clock source: 1::1
clock stratum: 16
clock status: configured, insane, valid, unsynced
reference clock ID: 0.0.0.0
reach: 0
current poll: 64
now: 6
offset: 0.0000 ms
delay: 0.00 ms
disper: 0.00 ms

Run the display ntp-service status command to view the status of the NTP service. For example, you can see that the clock status field is displayed as synchronized.

<HUAWEI>display ntp-service status
 clock status: synchronized
 clock stratum: 2
 reference clock ID: LOCAL (0)
 nominal frequency: 60.0002 Hz
 actual frequency: 60.0002 Hz
 clock precision: 2^18
 clock offset: 0.0000 ms
 root delay: 0.00 ms
 root dispersion: 0.00 ms
 peer dispersion: 10.00 ms
 reference time: 15:51:36.259 UTC Apr 25 2005 (C6179088.426490A3)
 synchronization state: clock synchronized

Run the display ntp-service trace command to trace the path of reference clock source from the local device. For example, you can trace the path of reference clock as below:

<HUAWEI> display ntp-service trace
server 127.0.0.1, stratum 5, offset 0.024099, synch distance 0.06337,
server 171.1.1.2, stratum 4, offset 0.028786, synch distance 0.04575,
server 201.1.1.2, stratum 3, offset 0.035199, synch distance 0.03075,
server 200.1.7.1, stratum 2, offset 0.039855, synch distance 0.01096,
refid 127.127.1.0

Run the display ntp-service bd-status command to view the status of each board on a Router. For example, you can see that the Clock Status field of the board is displayed as synchronized.

<HUAWEI> display ntp-service bd-status
Board ID              : 17
Sync Source           : 127.127.1.0
NTP Server Configured : No
Clock Status          : synchronized
Offset                : 0.7 ms
Clock Precision       : 2^17
Poll                  : 8
Reference Time        : 17:04:55.236 UTC Sep 11 2009(CE5501B7.3C8D4BAD)
Current Time          : 17:05:39.359 UTC Sep 11 2009(CE5501E3.5C0DB270)