NE40E-M2 V800R010C10SPC500 Configuration Guide - WAN Access 01

This is NE40E-M2 V800R010C10SPC500 Configuration Guide - WAN Access
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the CE1 Interface Configuration

Verifying the CE1 Interface Configuration

After you configure a channelized E1 (CE1) interface, verify the configurations and status of the CE1 interface.

Prerequisites

A CE1 interface has been configured.

Procedure

  • Run the display interface serial [ interface-number ] command to check the status and statistics of a serial interface.
  • Run the display controller e1 [ controller-number ] command to check the configurations and status of a CE1 interface.

Example

Run the display interface serial command. The command output displays the status and statistics of a specified serial interface.
<HUAWEI> display interface serial 0/1/0:2
Serial0/1/0:2 current state : UP (ifindex: 292)
Line protocol current state : UP 
Description:
Route Port,The Maximum Transmit Unit is 1500, Hold timer is 10(sec)
Derived from E1 0/1/0, Timeslot(s) Used: 1-31, baudrate is 1984000 bps
Internet protocol processing : disabled
Link layer protocol is PPP
LCP opened, MP opened
CRC: CRC-32
Scramble disabled
Current system time: 2013-08-07 10:09:12
Statistics last cleared:2013-08-07 09:41:29
  Traffic statistics:
    Last 300 seconds input rate 61 bits/sec, 0 packets/sec            
    Last 300 seconds output rate 61 bits/sec, 0 packets/sec           
    Input: 332 packets, 12764 bytes                                   
    Input error: 0 shortpackets, 0 longpackets, 0 CRC, 0 lostpackets  
    Output: 332 packets, 12800 bytes                                  
    Output error: 0 lostpackets                                       
    Output error: 0 overrunpackets, 0 underrunpackets   
    Last 300 seconds input utility rate:  0.01%                       
    Last 300 seconds output utility rate: 0.01%              
Run the display controller e1 command. The command output displays the configurations and status of the specified CE1 interface.
<HUAWEI> display controller e1 0/1/0
E1 0/1/0 current state : UP (ifindex: 7)
Description: HUAWEI, Quidway Series, E1 0/1/0 Interface             
                                                                        