Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring ES-TCA Alarm Thresholds on a CE1 Interface

Configuring ES-TCA Alarm Thresholds on a CE1 Interface

If the threshold for triggering an ES-TCA alarm is set and the number of E1 code errors exceeds the threshold, an alarm will be generated.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run controller e1 controller-number

    The view of a specific CE1 interface is displayed.

  3. Run trap-threshold es-tca trigger-threshold trigger-threshold resume-threshold resume-threshold

    The thresholds for triggering and clearing an ES-TCA alarm are set.