NE40E-M2 V800R010C10SPC500 Configuration Guide - WAN Access 01

This is NE40E-M2 V800R010C10SPC500 Configuration Guide - WAN Access
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Maintaining a CPOS Interface

Maintaining a CPOS Interface

You can test the bit error rate of a CPOS E1 link to maintain the CPOS interface.

Testing the Bit Error Rate of a CPOS E1 Link

The testing results can be used to locate link faults.

Context

NOTE:

This configuration process is supported only on the Admin-VS.

When faults occur on a CPOS E1 link, you can run the test connectivity controller cpos e1 command for fault locating.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run test connectivity controller cpos e1 controller-number { unframed | channelized timeslot-list slot-list } duration time

    The bit error rate is tested on a specified CPOS E1 link.

Clearing Error Statistics and Alarm Status Information on an E1 Interface or on a CPOS Interface's E1 Channels

Context

NOTE:

This configuration process is supported only on the Admin-VS.

This section describes how to clear error statistics and alarm status information on an E1 interface or on a CPOS interface's E1 channels.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the reset e1 counters controller cpos controller-number e1 e1-number command to clear error statistics and alarm status information on a CPOS interface's E1 channels or run the reset e1 counters controller e1 controller-number command to clear error statistics and alarm status information on an E1 interface.

Monitoring the Physical Status of E1 Links

To ensure correct link connections, you must monitor the physical status of E1 links.

Context

Monitoring the physical status of E1 links can help you locate E1 link faults, ensuring correct link connections. You can configure the system to monitor the physical status of multiple E1 links simultaneously while not affecting existing services.

Perform the following steps on a device to be checked:

Procedure

  1. Run monitor e1 { interface-type interface-number | interface-name } &<1-16> [ interval interval [ times times ] | times times [ interval interval ] ]

    The physical status of E1 links is monitored.