No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

NE40E-M2 V800R010C10SPC500 Configuration Guide - WAN Access 01

This is NE40E-M2 V800R010C10SPC500 Configuration Guide - WAN Access
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring CPOS Interface Interconnection

Example for Configuring CPOS Interface Interconnection

This section provides an example on how to interconnect devices through CPOS interfaces and how to configure MP-group interfaces for link bundling.

Networking Requirements

On the network shown in Figure 5-6, Device A and Device B need to communicate with each other through CPOS interfaces, and MP-group interfaces need to be configured for link bundling.

Figure 5-6 Configuring CPOS interface interconnection
NOTE:

In this example, interface1 and interface2 represent CPOS 0/3/0 and CPOS 0/2/9, respectively.



Configuration Roadmap

The configuration roadmap is as follows:

  1. Configure a working mode for CPOS interfaces and channelize them into synchronous serial interfaces.

  2. Configure MP-group interfaces and add the synchronous serial interfaces to the MP-group interfaces.

Data Preparation

To complete the configuration, you need the following data:

  • Channel number and timeslot number of each E1 channel

  • IP addresses of MP-group interfaces

NOTE:

The interface to be added to an MP-group interface must have the same slot number and card number as the MP-group interface.

The timeslot channels of the serial interfaces on Device A must be the same as those on Device B.

Procedure

  1. Configure a working mode for CPOS interfaces and channelize them into synchronous serial interfaces.

    # Create synchronous serial interfaces on the CPOS interface of Device A.

    <HUAWEI> system-view
    [~HUAWEI] sysname DeviceA
    [*DeviceA] controller cpos 0/3/0
    [*DeviceA-Cpos0/3/0] e1 1 channel-set 1 timeslot-list 1-15
    [*DeviceA-Cpos0/3/0] e1 2 channel-set 1 timeslot-list 16-31
    [*DeviceA-Cpos0/3/0] undo shutdown
    [*DeviceA-Cpos0/3/0] commit
    [~DeviceA-Cpos0/3/0] quit

    # # Create synchronous serial interfaces on the CPOS interface of Device B.

    <HUAWEI> system-view
    [~HUAWEI] sysname DeviceB
    [*DeviceB] controller cpos 0/2/9
    [*DeviceB-Cpos0/2/9] e1 1 channel-set 1 timeslot-list 1-15
    [*DeviceB-Cpos0/2/9] e1 2 channel-set 1 timeslot-list 16-31
    [*DeviceB-Cpos0/2/9] undo shutdown
    [*DeviceB-Cpos0/2/9] commit
    [~DeviceB-Cpos0/2/9] quit

  2. Configure MP-group interfaces and add the synchronous serial interfaces to the MP-group interfaces.

    # Create an MP-group interface on Device A.

    [~DeviceA] interface mp-group 0/3/0
    [*DeviceA-Mp-group0/3/0] ip address 10.1.1.1 255.255.255.0
    [*DeviceA-Mp-group0/3/0] undo shutdown
    [*DeviceA-Mp-group0/3/0] commit
    [~DeviceA-Mp-group0/3/0] quit

    # Add the synchronous serial interfaces to the MP-group interface on Device A.

    [~DeviceA] interface serial 0/3/0/1:1
    [~DeviceA-Serial0/3/0/1:1] link-protocol ppp
    [*DeviceA-Serial0/3/0/1:1] ppp mp mp-group 0/3/0
    [*DeviceA-Serial0/3/0/1:1] commit
    [~DeviceA-Serial0/3/0/1:1] quit
    [~DeviceA] interface serial 0/3/0/2:1
    [~DeviceA-Serial0/3/0/2:1] link-protocol ppp
    [*DeviceA-Serial0/3/0/2:1] ppp mp mp-group 0/3/0
    [*DeviceA-Serial0/3/0/2:1] commit
    [~DeviceA-Serial0/3/0/2:1] quit

    # Create an MP-group interface on Device B.

    [~DeviceB] interface mp-group 0/2/9
    [*DeviceB-Mp-group0/2/9] ip address 10.1.1.2 255.255.255.0
    [*DeviceB-Mp-group0/2/9] undo shutdown
    [*DeviceB-Mp-group0/2/9] commit
    [~DeviceB-Mp-group0/2/9] quit

    # Add the synchronous serial interfaces to the MP-group interface on Device B.

    [~DeviceB] interface serial 0/2/9/1:1
    [~DeviceB-Serial0/2/9/1:1] link-protocol ppp
    [*DeviceB-Serial0/2/9/1:1] ppp mp mp-group 0/2/9
    [*DeviceB-Serial0/2/9/1:1] commit
    [~DeviceB-Serial0/2/9/1:1] quit
    [~DeviceB] interface serial 0/2/9/2:1
    [~DeviceB-Serial0/2/9/2:1] link-protocol ppp
    [*DeviceB-Serial0/2/9/2:1] ppp mp mp-group 0/2/9
    [*DeviceB-Serial0/2/9/2:1] commit
    [~DeviceB-Serial0/2/9/2:1] quit

  3. Verify the configuration.

    # On Device A, ping the IP address of the MP-group interface on Device B. The command output shows that the ping is successful.

    [~DeviceA] ping 10.1.1.2
    PING 10.1.1.2: 56  data bytes, press CTRL_C to break
        Reply from 10.1.1.2: bytes=56 Sequence=1 ttl=255 time=29 ms
        Reply from 10.1.1.2: bytes=56 Sequence=2 ttl=255 time=31 ms
        Reply from 10.1.1.2: bytes=56 Sequence=3 ttl=255 time=29 ms
        Reply from 10.1.1.2: bytes=56 Sequence=4 ttl=255 time=30 ms
        Reply from 10.1.1.2: bytes=56 Sequence=5 ttl=255 time=30 ms
      --- 10.1.1.2 ping statistics ---
        5 packet(s) transmitted
        5 packet(s) received
        0.00% packet loss
        round-trip min/avg/max = 29/29/31 ms

Configuration Files

  • Device A configuration file

    #
    sysname DeviceA
    #
    controller Cpos0/3/0
     e1 1 channel-set 1 timeslot-list 1-15
     e1 2 channel-set 1 timeslot-list 16-31
     undo shutdown
    #
    interface Mp-group0/3/0
    #
    interface Serial0/3/0/1:1
     link-protocol ppp
     ppp mp Mp-group0/3/0
    #
    interface Serial0/3/0/2:1
     link-protocol ppp
     ppp mp Mp-group0/3/0
    #
    return
  • Device B configuration file

    #
    sysname DeviceB
    #
    controller Cpos0/2/9
     e1 1 channel-set 1 timeslot-list 1-15
     e1 2 channel-set 1 timeslot-list 16-31
     undo shutdown
    #
    interface Mp-group0/2/9
    #
    interface Serial0/2/9/1:1
     link-protocol ppp
     ppp mp Mp-group0/2/9
    #
    interface Serial0/2/9/2:1
     link-protocol ppp
     ppp mp Mp-group0/2/9
    #
    return