Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Testing the Bit Error Rate of a CE1 Interface

Testing the Bit Error Rate of a CE1 Interface

The testing results can be used to locate link faults.

Context

NOTE:

This configuration process is supported only on the Admin-VS.

When faults occur on a CE1 interface, you can run the test connectivity controller e1 command for fault locating.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run test connectivity controller e1 controller-number { unframed | channelized timeslot-list slot-list } duration time

    The bit error rate is tested on a specified CE1 interface.