Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Clock Mode for an E3 Interface

Configuring a Clock Mode for an E3 Interface

An E3 interface works either in master clock mode or slave clock mode.

Context

An E3 interface has two clock modes:

  • Master clock mode: The E3 interface uses internal clock signals.

  • Slave clock mode: The E3 interface uses clock signals provided by an external device.

When two Routers are directly connected through E3 interfaces, configure one E3 interface as the master clock and the other E3 interface as the slave clock.

By default, an E3 interface works in master clock mode.

Perform the following steps on a router.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run controller e3 controller-number

    The specified E3 interface view is displayed.

  3. Run clock { master | slave }

    The clock mode of the E3 interface is configured.

  4. Run commit

    The configuration is committed.