NE40E-M2 V800R010C10SPC500 Installation Guide

This is NE40E-M2 V800R010C10SPC500 Installation Guide
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DC Power Distribution Guide

DC Power Distribution Guide

Do not install power cables when the power is on. This is to avoid injuries.

Figure 8-11 Schematic diagram of the DC power distribution

DC Power Supply System

Figure 8-12 DC power module

Table 8-3 Technical parameters of the DC power module

Item

Description

Number of DC power modules

2

Input voltage range

-38.4 V DC - -72 V DC

Maximum input current

10 A

Maximum output power

500 W

Table 8-4 Cable specifications

Distance from the PDF to the device

Item

Description

BOM number

Remark

Shorter than or equal to 25 m (82.02 ft)

DC power cable

4 mm2(12AWG)

25030701

Blue DC power cable

25030700

Black DC power cable

Terminal

Quick installation terminal

14180340

It is connected to the device

Longer than 25 m (82.02 ft), Shorter than or equal to 35 m (114.83 ft)

DC power cable

6 mm2(10AWG)

25030697

Blue DC power cable

25030703

Black DC power cable

Terminal

Quick installation terminal

14180340

It is connected to the device

Longer than 35 m (114.83 ft)

-

A power distribution frame or the first power cabinet of a row should be placed near the device.

-

-

Table 8-5 PDF circuit breaker specifications

Item

Description

Remarks

Circuit breaker of each channel

≥16 A - ≤40 A

For hierarchical power supplying protection, the current of the circuit breaker at the user side should be no less than that of the power module (12.5 A).

Installing Power Cables

  1. Install the power cable terminal.
    Figure 8-13 Power cable terminal installation

  2. Attach temporary labels to both ends of each power cable.
  3. Route power cables along the cable ladder and lay them on the chassis.
  4. Connect one end of each power cable to the corresponding terminal and the other end to the PDF.
    Figure 8-14 Installing Power Cables

  5. Use cable ties to bundle cables every 150 mm upwards from the bottom and fasten the cables to the cable tray.
  6. Attach permanent labels 20 mm from both ends of each power cable.
NOTE:

The distance between power cables, ground cables, and signal cables must be greater than 30 mm.

NOTE:

To ensure that the power cable is as long as required, perform the following steps to install a power cable:

  1. Prepare a power cable a little longer than the distance between the power module and PDF.
  2. Install a terminal on one end of the power cable and connect the terminal to the device.
  3. Route the power cable, bind it to the cable tray, and cut any excess length of the cable. Install a terminal on the other end of the power cable and connect the terminal to the PDF.