NE40E-M2 V800R010C10SPC500 Installation Guide

This is NE40E-M2 V800R010C10SPC500 Installation Guide
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Labels for Trunk Cables Between the Device and a DDF

Labels for Trunk Cables Between the Device and a DDF

Meaning of the Labels for Trunk Cables Between the Device and a DDF

Table 6-6 provides information on a label for a trunk cable between the device and a DDF.

Table 6-6 Information on a label for a trunk cable between the device and a DDF

Content

Meaning

Description

MN-B-C-D-R/T

MN: cabinet number

The row and column number of a cabinet. For example, A01 indicates row A, column 01.

B: chassis number

A two-digit number that indicates the position of a chassis in a cabinet, for example, 03. Chassis are numbered from bottom to top.

C: physical slot number

A two-digit number, for example, 01. Slots are numbered from top to bottom and from left to right.

D: interface number

A two-digit number, for example, 01. Interfaces are numbered from top to bottom and from left to right.

R: receive optical interface

T: transmit optical interface

-

DDF-MN-B-C-D/R/T

MN: DDF number

M identifies the row number of a DDF. Rows are numbered from A to Z from front to back.

N identifies the column number of a DDF. Columns are numbered from 01 to 99 from left to right.

For example, G01 indicates row G, column 01.

B: row number of a terminal device

A two-digit number ranging from 01 to 99, for example, 01.

C: column number of the terminal device

DDF-MN-B-C-D/R/T

D: terminal type

R: receive optical interface

T: transmit optical interface

Valid values for D are A and B. A indicates that the DDF is connected to an optical network device; B indicates that the DDF is connected to a switching device.

Example Label

Figure 6-13 shows an example label for a trunk cable between the device and a DDF.

Figure 6-13 Example label for a trunk cable between the device and a DDF

The label shown in Figure 6-13 contains the following information:

  • "A01-03-01-01-R" indicates that the local end of the trunk cable is connected to receive interface 01 on slot 01 in chassis 03 in the cabinet in row A, column 01.
  • "DDF-G01-01-01-AR" indicates that the other end of the trunk cable is connected to the receive interface of terminal A in row 01, column 01 of the DDF in row G, column 01.