Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling Auto Loop Detection

Enabling Auto Loop Detection

Context

Perform the following steps on each PE.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run loop-detect trigger enable

    Auto loop detection is enabled.

  3. (Optional) Run loop-detect trigger min-port-uptime

    The period after which the system starts Auto loop detection on an interface is specified. The period is counted after the interface status changes from Down to Up.

  4. (Optional) Run loop-detect trigger min-slot-uptime

    The period after which the system starts Auto loop detection is specified. The period is counted after the control board starts.

  5. Run commit

    The configuration is committed.

Translation