Configuration Guide - VPN 01

NE05E and NE08E V300R003C10SPC500

This is NE05E and NE08E V300R003C10SPC500 Configuration Guide - VPN
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Creating a Remote CCC Connection

Creating a Remote CCC Connection

Creating remote CCC connections enables two CEs that connect to different PEs to communicate.

Context

To create a remote CCC connection, configure the inbound interface, next hop IP address, in-label, and out-label for the connection on the PEs connecting to different CEs, and configure two bidirectional static CR-LSPs on the P devices deployed between the PEs. A remote CCC connection is unidirectional, and therefore two such connections must be created.

Procedure

  • PE configurations

    Perform the following steps on the PEs on both ends of a VC:

    1. Run system-view

      The system view is displayed.

    2. Run ccc ccc-connection-name interface interface-type1 interface-number1 [ raw | tagged ] in-label in-label-value out-label out-label-value { nexthop nexthop-address | out-interface interface-type2 interface-number2 } [ control-word | no-control-word ]Or,ccc ip-interworking ccc-connection-name interface interface-type1 interface-number1 [ raw | tagged ] in-label in-label-value out-label out-label-value { nexthop nexthop-address | out-interface interface-type2 interface-number2 } [ control-word | no-control-word ]

      A remote CCC connection is created.

      If the outbound interface specified on a PE is a non-P2P interface, you must configure nexthop to specify a next hop IP address in this command.

    3. (Optional) Run ccc ccc-name description description-text

      A description is configured for the remote CCC connection.

    4. Run commit

      The configuration is committed.

  • P device configurations

    Perform the following steps on the P devices along the VC:

    1. Run system-view

      The system view is displayed.

    2. Run static-cr-lsp transit lsp-name incoming-interface interface-type interface-number in-label in-label { nexthop next-hop-address | outgoing-interface interface-type interface-number } * out-label out-label

      The P device is configured as the transit LSR for a static CR-LSP.

      Bidirectional static CR-LSPs must be configured on all P devices deployed between the PEs for remote CCC connections to transmit CCC data only.

      If the outbound interface specified on a P device is a non-P2P interface, you must configure nexthop to specify a next hop IP address in this command.

    3. Run commit

      The configuration is committed.