Configuration Guide - VPN 01

NE05E and NE08E V300R003C10SPC500

This is NE05E and NE08E V300R003C10SPC500 Configuration Guide - VPN
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring Fast Fault Notification

(Optional) Configuring Fast Fault Notification

OAM mapping and physical-layer fault notification can accelerate AC fault detection and notification.

Context

Fast fault notification is classified into the following types:
NOTE:

When a PW encounters a fault, OAM mapping does not trigger AC interfaces to go Down. If PEs and CEs support Ethernet OAM, using OAM mapping is recommended.

Procedure

  • Configure OAM mapping.
    1. Run system-view

      The system view is displayed.

    2. Run interface interface-type interface-number

      The AC interface view is displayed.

      NOTE:

      The AC interface must be an Ethernet sub-interface.

    3. Run mpls l2vpn oam-mapping 1ag md md-name ma ma-name

      OAM mapping is enabled to associate PW OAM with AC OAM.

      • Ethernet OAM for ACs must be configured before the mpls l2vpn oam-mapping 1ag md md-name ma ma-name command is run.

      • After running the mpls l2vpn oam-mapping command, run the display mpls l2vpn oam-mapping [ interface interface-type interface-number ] command to check VC status. In the command output, Local AC OAM State indicates the AC link status.

    4. Run commit

      The configuration is committed.

  • Configure physical layer fault notification.
    1. Run system-view

      The system view is displayed.

    2. Run interface interface-type interface-number

      The AC interface view is displayed.

      • The AC interface must be an Ethernet main interface.

      • This interface must have a VC configured.

    3. Run mpls l2vpn trigger if-down

      Physical layer fault notification is enabled.

    4. Run commit

      The configuration is committed.