Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Single-Root P2MP TE Tunnel

Configuring a Single-Root P2MP TE Tunnel

This section describes how to configure a single-root P2MP TE tunnel to minimize traffic redundancy.

Procedure

  • Perform the following steps on the root node:
    1. Run system-view

      The system view is displayed.

    2. Run vsi vsi-name

      A VSI is created, and the VSI view is displayed.

    3. (Optional) Run ignore-ac-state

      The VSI is configured to ignore AC status changes.

      By default, AC status affects VSI status.

    4. Run inclusive-provider-tunnel

      The VSI-Inclusive view is created and displayed.

    5. Run root

      The current device is specified as the root node for multicast VPLS, and the VSI-Inclusive-Root view is displayed.

    6. Run mpls-te

      The tunnel type is specified as P2MP TE for the local VSI, and the VSI-Inclusive-Root-TE view is displayed.

    7. Run p2mp { dynamic | te-template template-name }

      A P2MP TE tunnel is created.

    8. Run commit

      The configuration is committed.

  • Perform the following steps on each leaf node:
    1. Run system-view

      The system view is displayed.

    2. Run vsi vsi-name

      A VSI is created, and the VSI view is displayed.

    3. Run inclusive-provider-tunnel

      The VSI-Inclusive view is created and displayed.

    4. Run leaf

      The current device is specified as a leaf node for multicast VPLS.

    5. Run commit

      The configuration is committed.