Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Creating a Local CCC Connection

Creating a Local CCC Connection

Creating a local CCC connection enables two CEs that connect to the same PE to communicate.

Context

When configured with a local CCC connection, the PE functions similar to a Layer 2 switch to directly transmit the CEs' packets without using LSPs.

Perform the following steps on a PE connecting two CEs:

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run mpls l2vpn

    MPLS L2VPN is enabled.

  3. Run quit

    Return to the system view.

  4. Run ccc [ ip-interworking ] ccc-connection-name interface interface-type1 interface-number1 [ access-port ] [ raw | tagged ] out-interface interface-type2 interface-number2 [ access-port ] [ raw | tagged ]

    A local CCC connection is created.

    • Because the local CCC connection is bidirectional, only one connection is required, and only the inbound and outbound interfaces of the connection need to be configured on the PE.
    • If the link encapsulation types on the two CEs are inconsistent, configure ip-interworking in this command to enable heterogeneous IP interworking for the local CCC connection.
    • The raw, tagged, and access-port parameters can be configured in this command only when this command is applied to Ethernet links. The access-port parameter applies only to Ethernet main interfaces.

  5. (Optional) Run ccc ccc-name description description-text

    A description is configured for the local CCC connection.

  6. Run commit

    The configuration is committed.