Hardware Description

NE05E and NE08E V300R003C10SPC500

This is NE05E and NE08E V300R003C10SPC500 Hardware Description
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

Item NE05E-SR NE05E-SQ NE08E-S6E NE08E-S9

Dimensions (H x W x D)

43.6 mm x 250 mm x 180 mm (1.72 in. x 9.84 in. x 7.09 in.)

44.45 mm x 442 mm x 220 mm (1.75 in. x 17.40 in. x 8.66 in.)

88.90 mm x 442 mm x 220 mm (3.50 in. x 17.40 in. x 8.66 in.)

155.58 mm x 442 mm x 220 mm (6.12 in. x 17.40 in. x 8.66 in.)

Weight (empty)

N/A

N/A

3.5 kg

  • DC:7.9 kg
  • AC:10.3 kg

Weight (full configuration)

1.7kg

  • DC:4.7kg
  • AC:4.9kg

9.17kg

  • NEJ1CXPA DC:17.32kg
  • NEJ1CXPA AC:18.04kg

Cabinet installation standard

IMB(3U), ETSI(21-inch), IEC(19-inch)

R01S100 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch)

R01S200 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch)

R01S300A Outdoor Cabinet, ETSI(21-inch), IEC(19-inch)

Typical power consumption

  • AC:12.8W
  • 2 channel DC System:82.8w
  • 2 channel AC System:85.6w
  • AC+DC system:84.2w
  • 2 channel DC System, with 160G CXP Protection:111W
  • 2 channel DC System, without 160G CXP Protection:57.45W
  • NEJ1CXPA DC System with CXP Protection:182w
  • NEJ1CXPA AC System with CXP Protection:254w

Typical heat dissipation

  • AC:41.5BTU/hour
  • 2 channel DC System:268.6BTU/hour
  • 2 channel AC System:277.7BTU/hour
  • AC+DC system:273.1BTU/hour
  • 2 channel DC System, with 160G CXP Protection:360.1BTU/hour
  • 2 channel DC System, without 160G CXP Protection:184.4BTU/hour
  • NEJ1CXPA DC:590.4BTU/hour
  • NEJ1CXPA AC:824.0BTU/hour

DC input voltage

  • input voltage range: 19V to 30V or -38.4V to -72V
  • input rated voltage: 24/-48V/-60V
  • input voltage range: -38.4V to -72V
  • input rated voltage: -48V/-60V
  • input voltage range: -38.4V to -72V
  • input rated voltage: -48V/-60V
  • input voltage range: -38.4V to -72V
  • input rated voltage: -48V/-60V

AC input voltage

  • input voltage range: 100 to 240V
  • input rated voltage: 110V/220V
  • input voltage range: 100 to 240V
  • input rated voltage: 110V/220V
  • input voltage range: N/A
  • input rated voltage: N/A
  • input voltage range: 100 to 240V
  • input rated voltage: 110V/220V

MTBF

40 years

40 years

40 years

40 years

MTTR

2 hours

2 hours

2 hours

2 hours

Availability

0.99999

0.99999

0.99999

0.99999

Redundant MPUs

-

-

1+1

1+1

Redundant fans

Natural heat dissipation, no fan

If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C.

If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.

If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.

Redundant power supply

N/A

1+1

1+1

1+1

Switching capacity

12 Gbit/s (Bidirectional)

272 Gbit/s (Bidirectional)

  • NED3CXPA :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed.
  • NED3CXPB :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed.
  • NEJ1CXPA :320 Gbit/s@256 bytes (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed.

Operating temperature

  • Long-term: -40°C to 60°C
  • Short-term: N/A
  • Remark: Restriction on the temperature variation rate: 30 °C/hour
  • Long-term: DC:-40°C to 65°C AC:-20°C to 65°C
  • Short-term: N/A
  • Remark: Restriction on the temperature variation rate: 30 °C/hour
  • Long-term: DC:-40°C to 65°C(160G)
  • Short-term: N/A
  • Remark: Restriction on the temperature variation rate: 30 °C/hour
  • Long-term: -40°C to 65°C
  • Short-term: N/A
  • Remark: Restriction on the temperature variation rate: 30 °C/hour

Storage temperature

-40°C to 70°C

-40°C to 70°C

-40°C to 70°C

-40°C to 70°C

Relative operating humidity

  • Long term: 5% to 95% RH, non-condensing
  • Short term: N/A
  • Long term: 5% to 95% RH, non-condensing
  • Short term: N/A
  • Long term: 5% to 95% RH, non-condensing
  • Short term: N/A
  • Long term: 5% to 95% RH, non-condensing
  • Short term: N/A

Relative storage humidity

5% to 100% RH, non-condensing

5% to 100% RH, non-condensing

5% to 100% RH, non-condensing

5% to 100% RH, non-condensing

Long-term operating altitude

≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude.

≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude.

≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude.

≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude.

Storage altitude

Lower than 5000 meters

Lower than 5000 meters

Lower than 5000 meters

Lower than 5000 meters

NOTE:
  1. In the physical dimensions shown in the table, the width (W) does not include the rack-mounting ears.
  2. Temperature and humidity are measured at 1.5 m (4.92 ft.) above the floor and 0.4 m (1.31 ft.) in front of the cabinet. There should be no protection board on the front or back of the cabinet.
  3. "Short-term" refers to continuous working time that does not exceed 96 hours and accumulated working time per year that does not exceed 15 days. If the working time exceeds either of these values, it is considered "long-term".
Translation