Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NE08E-S9 Fan

NE08E-S9 Fan

A FAN board of NE08E-S9.

Overview

Table 4-186 Fan attributes

Attribute

Description

Description

NE08E-S9 FAN

BOM

02312BDQ

Model

NEJD002FAN00

Table 4-187 Mapping products and versions

Product

Slot ID

Earliest Software Version

NE08E-S9

slot 14

V300R003C10

Appearance



Panel

Table 4-188 Indicators

Indicator

Description

Status Description

FAN

Fan status indicator

  • On (green): the fans are working normally.
  • On (red): the fans are working abnormally.
  • Off: the fans are not powered.
Table 4-189 ESD Strap Jack

Interface Name

Description

ESD

The ESD wrist strap should be connected to this jack for proper grounding of the human body.

Functional Specifications

  • Accesses power supplies for driving fans.
  • Provides start-delay for the power supply of the fans, protects fans against overcurrent, and filters the lower frequency.
  • Intelligently adjusts the rotating speed of fans to ensure proper heat dissipation of the system.
  • Reports information about the fan rotating speed, environment temperature, alarms, version number, and board in-position information.
  • Provides alarm indicators.

Heat Dissipation

Figure 4-4 NE08E-S9 air duct

  • Heat dissipation holes of air intake and exhaust vents on NE08E-S9 must be kept clean and unblocked.
  • A distance of at least 50 mm must be reserved at the air intake/exhaust vent on NE08E-S9 to ensure good ventilation.
  • Filler panels must be installed on unused slots. In addition, on NE08E-S9, heat must be dissipated by drawing in air from the left and expelling out the air from the right.
  • When NE08E-S9 is installed in a cabinet, temperature inside the cabinet must be within the temperature range and the air duct of the cabinet must be consistent with that of NE08E-S9.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

156.4 mm x 40.0 mm x 238.0 mm

Typical power consumption

  • Low rate: 8.8 W
  • Medium rate: 26 W
  • High rate: 154 W

Typical heat dissipation

  • Low rate: 28.6 BTU/hour
  • Medium rate: 84.4 BTU/hour
  • High rate: 500.0 BTU/hour

Weight

1.2 kg