Hardware Description

NE05E and NE08E V300R003C10SPC500

This is NE05E and NE08E V300R003C10SPC500 Hardware Description
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NE05E-SQ Chassis

NE05E-SQ Chassis

An NE05E-SQ supports only hot swap of power modules. You can install two DC or AC power modules on a device and also both DC and AC power modules.

Overview

Table 3-10 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

Remarks

NE05E-SQ

NE05E-SQ - 2 channels DC entries, with 4*10GE(o), 8*10GE/GE/FE(o), 8*GE/FE(o), 8*GE/FE(e)

02350WSF

NECMHSTA0200

V300R001C10

auxiliary material package included

NE05E-SQ

NE05E-SQ - 2 channels DC entries, with 4*10GE(o), 8*10GE/GE/FE(o), 8*GE/FE(o), 8*GE/FE(e)

02350VNG

NECMHSTA0211

V300R001C10

auxiliary material package excluded

NE05E-SQ

NE05E-SQ - 2 channels AC entries, with 4*10GE(o), 8*10GE/GE/FE(o), 8*GE/FE(o), 8*GE/FE(e)

02350WSG

NECMHSTB0200

V300R001C10

auxiliary material package included

NE05E-SQ

NE05E-SQ - 2 channels AC entries, with 4*10GE(o), 8*10GE/GE/FE(o), 8*GE/FE(o), 8*GE/FE(e)

02350VNH

NECMHSTB0211

V300R001C10

auxiliary material package excluded

NOTE:
In specific areas, as the auxiliary materials are different, the sales BOM numbers may be different. Different sales BOM numbers may correspond to the same description in the device attribute table. The actual sales BOM number in an area prevails.

Appearance

Figure 3-3 Appearance of the NE05E-SQ

Panel

Table 3-11 Buttons

Button

Description

RST

There is only one RST button for resetting the device.

The RST button can also be used to delete passwords and configuration files on the device. Once you press the RST button, the device starts to reset. Then you press and hold down the RST button 35s to 45s until the SATA and ALM indicators blink green. Then release the RST button so that the device starts to automatically delete passwords and configuration files. If you keep holding down the RST button (approximately 10s) until the three indicators are not blinking green simultaneously, the device only resets and does not delete the passwords and configuration files.

Table 3-12 Indicators

Indicator

Description

Status Description

STAT

Board status indicator

  • On (green): the device is working normally.
  • On (red): the device hardware is faulty.
  • On (orange): the device is not loaded with the logic.
  • Off: the device is not running or no power is input.

ALM

Alarm indicator

  • On (red): critical alarms are generated.
  • On (orange): major or minor alarms are generated.
  • Off: no alarms are generated.

LINK

Connection status indicator

  • On (green): the data interface is transmitting or receiving data.
  • Off: the physical port connection fails.

ACT

Transmitting/receiving status indicator

  • Blinking (orange): the data interface is not transmitting or receiving data.
  • Off: the data interface is not transmitting or receiving data.

L/A

Connection/data transmission status indicator

  • On (green): the connection on the physical port is normal.
  • Blinking (orange or green): The connection on the physical port is normal, and data is received or transmitted on the port.
  • Off: the physical connection fails.
Table 3-13 Management interfaces

Interface Name

Interface Type

Connector Type

Description

Cable

OAM

-

USB

USB NM interface

-

ETH/OAM

FE/RS-232

RJ-45

10M/100M interface that can function as an NM interface or console interface

ETH/OAM Management Cables

CLK

-

RJ-45

Clock input/output interface

Clock Cables

TOD

-

RJ-45

Time input/output interface

Clock Cables

ALMI/ALMO

-

RJ-45

Alarm input/output interface

Alarm Input/Output Cables

Table 3-14 Service interfaces

Interface Name

Interface Type

Connector Type

Description

Cable

XGE(0-3)

10GE

SFP+

10GE service signal input and output interface

Optical Fibers

XGE/GE/FE(4-11)

FE/GE/10GE

SFP+/SFP

FE/GE/10GE service signal input and output interface
NOTE:
The 1.25/9.953/10.3125Gbps SFP+ optical module is only supported on the XGE/GE/FE(4-11) port on the NE05E-SQ device, and the optical module is reported to be mismatched on other ports.

Optical Fibers

Ethernet Cables

NE05E-SQ:GE/FE(12-19)

FE/GE

SFP

FE/GE service signal input and output interface

Optical Fibers

NE05E-SQ:GE/FE(20-27)

FE/GE

RJ-45

FE/GE service signal input and output interface

Ethernet Cables

Table 3-15 Pins of the ETH/OAM interface

Front View

Pin

Usage



1

Transmit positive of the NM network port

2

Transmit negative of the NM network port

3

Receive positive of the NM network port

4

Grounding end of the Console interface

5

Receive end of the Console interface

6

Receive negative of the NM network port

7

Unspecified

8

Transmit end of the Console interface

Table 3-16 Pins of the CLK interface

Front View

Pin

Usage



1

Negative receive end of external clock

2

Positive receive end of external clock

3

Unspecified

4

Negative transmit end of external clock

5

Positive transmit end of external clock

6

Unspecified

7

Unspecified

8

Unspecified

Table 3-17 Pins of the TOD interface

Front View

Pin

Working Mode

External Time Input

(1PPS + Time Information)

External Time Output

(1PPS + Time Information)



1

Unspecified

Unspecified

2

Unspecified

Unspecified

3

Negative input for the 1pps signal

(RS422 level)

Negative output for the 1pps signal

(RS422 level)

4

Grounding end

Grounding end

5

Grounding end

Grounding end

6

Positive input for the 1pps signal

(RS422 level)

Positive output for the 1pps signal

(RS422 level)

7

Negative input for time information

(RS422 level)

Negative output for time information

(RS422 level)

8

Positive input for time information

(RS422 level)

Positive output for time information

(RS422 level)

NOTE:

The TOD interfaces can be configured so that they can work in one of the preceding two working modes.

Table 3-18 Pins of the ALMI/ALMO interface

Front View

Pin

Usage



1

Input for the digital parameter

2

Grounding end

3

Input for the digital parameter

4

Input for the digital parameter

5

Grounding end

6

Grounding end

7

Positive output for the digital parameter

8

Negative output for the digital parameter

Interface Numbering Rules

On the NE05E-SQ, an interface is numbered in the format of "slot number/subcard number/port number". The following part describes the details:

  • Slot number

    The slot number of NE05E-SQ is always 0.

  • Subcard number

    The NE05E-SQ does not support subcards. Therefore, the subcard number of the NE05E-SQ is fixed as 2.

  • Port number

    The port numbers of service interfaces on the NE05E-SQ begin with 0. Port numbering depends on the number of interfaces on the NE05E-SQ.

NOTE:
The OAM interface is always numbered Ethernet 0/0/0.

Label

Figure 3-4 Label Description

Table 3-19 Label description

Figure

Label Name

Description



Backplane bar code label

The bar code of the backplane will be retrieved by device as the equipment serial number (ESN).



ESD protection label

The label suggests the electrostatic-sensitive equipment.



Grounding label

This label suggests the position of the grounding terminal.



Heat hazard label

This label suggests that the surface temperature is high and it may cause body injury.



Certificate label

This label suggests that the device is qualified.



Product nameplate label

This label suggests the product name and certification.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

44.45 mm x 442 mm x 220 mm (1.75 in. x 17.40 in. x 8.66 in.)

Weight (empty)

N/A

Weight (full configuration)

  • DC:4.7kg
  • AC:4.9kg

Cabinet installation standard

R01S100 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch)

Typical power consumption

  • 2 channel DC System:82.8w
  • 2 channel AC System:85.6w
  • AC+DC system:84.2w

Typical heat dissipation

  • 2 channel DC System:268.6BTU/hour
  • 2 channel AC System:277.7BTU/hour
  • AC+DC system:273.1BTU/hour

DC input voltage

  • input voltage range: -38.4V to -72V
  • input rated voltage: -48V/-60V

AC input voltage

  • input voltage range: 100 to 240V
  • input rated voltage: 110V/220V

MTBF

40 years

MTTR

2 hours

Availability

0.99999

Redundant fans

If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C.

Redundant power supply

1+1

Switching capacity

272 Gbit/s (Bidirectional)

Operating temperature

  • Long-term: DC:-40°C to 65°C AC:-20°C to 65°C
  • Short-term: N/A
  • Remark: Restriction on the temperature variation rate: 30 °C/hour

Storage temperature

-40°C to 70°C

Relative operating humidity

  • Long term: 5% to 95% RH, non-condensing
  • Short term: N/A

Relative storage humidity

5% to 100% RH, non-condensing

Long-term operating altitude

≤ 4000 meters. If the altitude is between 1800 meters and 4000 meters, the operating temperature of the device must decrease by 1°C for every 220 meter increase in altitude.

Storage altitude

Lower than 5000 meters