No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CloudEC V600R019C00 Troubleshooting (Enterprise On-premises, Convergent Conference)

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MCU Interworking Fault

MCU Interworking Fault

Symptom

The USM fails to connect to the MCU. Conferences cannot be held in the hosted scenario.

Possible Causes

  • The MCU is not registered.
  • The MCUL link is faulty.

Troubleshooting Method

The MCU connects to the USM using the following two steps. You can locate the fault based on the steps.

  1. The MCU initiates registration using SIP messages.
  2. After registration, the USM connects to the MCU as a TCP client.

Procedure

  1. Run the DSP MCU command to check whether the MCU is registered.
    • Yes: Go to 2.
    • No: Enable SIP message tracing (ensure that the REGISTER message is selected). Check whether REGISTER messages are received from the MCU. If no, check related configurations on the MCU.
  2. Run the DSP MCUL command to check whether the MCUL link is normal.
    • Yes: The fault is not an MCU interworking fault.
    • No: Verify that the MCU IP address and the password are correctly configured on the MCUL.