Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Data Is Inconsistent Between Tables and Curves on Module Management Page of the LMT

Data Is Inconsistent Between Tables and Curves on Module Management Page of the LMT

Symptom

If the Huawei Operation & Maintenance System has run for a long period of time, data inconsistency may occur between the table and the curve displayed on the Module Management page, as shown in Figure 6-46.

Figure 6-46 Data inconsistency between the table and the curve displayed on the Module Management page

Possible Causes

The Huawei Operation & Maintenance System has run for a long period of time.

Fault Diagnosis

Check whether the Huawei Operation & Maintenance System has run for a long period of time.

Procedure

  1. Deselect the module and select the module again, then check whether data in the table is consistent with that in the curve:

    • Yes: No further action is required.
    • No: Go to 2.

  2. Close the Module Management page.
  3. Open the Module Management page again, select a module, and check whether data in the table is consistent with that in the curve:

    • Yes: No further action is required.
    • No: Go to 4.

  4. Exit Huawei Operation & Maintenance System.
  5. Log in to Huawei Operation & Maintenance System.
  6. Open the Module Management page again, select a module, and check whether data in the table is consistent with that in the curve:

    • Yes: No further action is required.
    • No: Go to 7.

  7. Contact Huawei technical support engineers.