Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Failed to Received CDRs on the CCF

Failed to Received CDRs on the CCF

Symptom

  • There is a possibility that CDRs are stacked on the NE side and fail to be sent to the CCF.
  • There is a possibility that the CCF reports ALM-25131 Stopped Receiving CDRs.
  • There is a possibility that the CCF reports ALM-25087 Diameter Link Abnormal.

Possible Causes

When the CCF fails to receive CDRs, the possible causes are as follows:

  • The CCF stops receiving CDRs.
  • Diameter links are faulty.

Troubleshooting Method

shows the flow for diagnosing CCF failure to receive CDRs in Figure 8-1.

Figure 8-1 The flow for diagnosis

Procedure

  1. In the Alarm Browse window of the HUAWEI Operation & Maintenance System, check whether ALM-25131 Stopped Receiving CDRs exists.
    • Yes: Go to 2.
    • No: Go to 3.
  2. Rectify the fault by referring to the handling procedure of ALM-25131 Stopped Receiving CDRs in the Alarm Help, and check whether the alarm is cleared.
    • Yes: No further action is required.
    • No: Go to 3.
  3. Log in to CDR Query and Browse System and check whether new CDR files are generated.
    • Yes: No further action is required.
    • No: Go to 4.
  4. Choose Alarm > Browse Alarms. On the displayed Browse Alarms tab page, check whether ALM-25087 Diameter Link Abnormal is generated.
    • Yes: Go to 5.
    • No: Go to 6.
  5. Rectify the fault by referring to the handling procedure of ALM-25087 Diameter Link Abnormal in the Alarm Help.
    • Yes: No further action is required.
    • No: Go to 6.
  6. Perform the operations described in Collecting iCG9815 Information.