No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HUAWEI NIP6800 Series V500 Hardware Guide

This document of the NIP6800 Series describes hardware structure, installation guide, and hardware maintenance. The content of this document includes the appearance and specifications of the product, the supported expansion cards, preparation before the installation, installation, cabling, and hardware replacement.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CR52FCBH Fan Module

CR52FCBH Fan Module

Multiple CR52FCBH fan modules reside side by side on the air exhaust vent. When a fan module fails to work, the system can still work at the ambient temperature of 40°C for a short time of period. The CR52FCBH fan modules are hot-swappable.

NOTE:

The heat dissipation system allows the device to operate at the ambient temperature for a short time as long as, at the time of failure, the system has not been operating continuously for more than 96 hours and the accumulated operation time of the system per year does not exceed 15 days.

Mapping

Table 1-84 describes the mapping between the CR52FCBH fan module and NIP6800 chassis.

Table 1-84  Mapping relationship

Fan Module

NIP6830

NIP6860

CR52FCBH

Not supported.

Supported; two fan modules in standard configuration for 1+1 backup.

Appearance

Figure 1-51 shows the CR52FCBH fan module appearance.

Figure 1-51  CR52FCBH fan module appearance

Table 1-85 describes the indicators on the CR52FCBH fan module.

Table 1-85  Description of the CR52FCBH fan module indicators

Indicator

Color

Description

STATUS

Green

If the indicator blinks once every 2 seconds (0.5 Hz), the fan module is working normally.

Red

If the indicator blinks once every 2 seconds (0.5 Hz), the fan module or PEM is faulty, or not all PEMs are powered on.

Technical specifications

Table 1-86 lists the technical specifications of the CR52FCBH fan module.

Table 1-86  Technical specifications of the CR52FCBH fan module

Item

Technical Specifications

Model

CR52FCBH

Part number

02120562

Dimensions (width x depth x height)

210.4 mm x 100 mm x 243.7 mm

Weight

3.4 kg

Power consumption (typical value)

30 W

Maximum noise

74 dB

Translation
Download
Updated: 2019-01-04

Document ID: EDOC1100059253

Views: 14492

Downloads: 26

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share