This document of the NIP6800 Series describes hardware structure, installation guide, and hardware maintenance. The content of this document includes the appearance and specifications of the product, the supported expansion cards, preparation before the installation, installation, cabling, and hardware replacement.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
AC Power Cable

AC Power Cable

This section describes the AC power cables of the NIP6800 that uses the AC power supply. Learn about the structure and specifications of the AC power cable before you make or purchase any for the NIP6800.

AC Power Cable of the NIP6830

This section describes the AC power cable of the NIP6830.

Structure and Appearance

The NIP6830 uses an external AC cable suite. In addition to Chinese standard AC power cables, local-standard AC power cables for Europe and North America are included. Figure 1-60 are for reference. Select power cables as required.

Figure 1-60  Chinese standard AC power cable (for the R4850G2 AC power module)

Technical Specifications

Table 1-93 shows the technical specifications for the R4850G2 AC power cable.

You must connect the AC cable in compliance with local standards and requirements.

Table 1-93  Technical specifications of the R4850G2 AC cable

Item

Specifications

Type of connector on the device

C19 straight female

Type of connector on the peer end

PI straight male, PI angle male, PF angle male, and PG angle male based on countries and regions

Cable length

3 m

Maximum voltage

125 V/250 V

Maximum current

16 A

AC Power Cable of the NIP6860

This section describes the AC power cable of the NIP6860.

NIP6860 AC Power Cable includes two parts:
  • Cable between the AC power chassis and the NIP6860
  • Between the AC power chassis and the AC Power Distribution cabinet
NOTE:

When the AC power passes through the AC power chassis, the convertor converts the AC power into the DC power. Therefore, the DC power cable needs to be used between the AC power chassis and the . For detailed information, please check Cables Between the AC power chassis and the NIP6860.

Structure and Appearance
Cable and terminal ( for the EPS200-4850A AC power chassis )

The NIP6860 uses electric and electronic cables as AC power cables, as shown in Figure 1-61.

Figure 1-61  Fixed-length electric and electronic cable ( for the EPS200-4850A AC power chassis )

An electric and electronic cable consists of a cable and two terminals. The terminals are mainly OT terminals.

Figure 1-62 shows the OT terminal without a cable.

Figure 1-62  OT terminal ( for the EPS200-4850A AC power chassis )

Cable (for the EPS200-4850B AC power chassis)

The NIP6860 uses an external AC cable suite. In addition to Chinese standard AC power cables, local-standard AC power cables for Europe and North America are included. Figure 1-63 is for reference. Select power cables as required.

Figure 1-63  Chinese standard AC power cable ( for the EPS200-4850B AC power chassis )

Cables Between the AC power chassis and the AC Power Distribution cabinet
Cables Between the EPS200-4850A AC Power Chassis and the AC Power Distribution Cabinet

If the power supply distance is longer than 50 m, you must place the power distribution cabinet closer to EPS200-4850A the AC power chassis.

If the distance between an EPS200-4850A AC power chassis and the power distribution cabinet is shorter than 50 m, use the AC power cable shown in Table 1-94.

Table 1-94  Cables between the EPS200-4850A AC power chassis and the AC power distribution cabinet

Item

Description

Cable Type

Two-wire AC power cable

Power Cable,300/500V,60227 IEC 10(BVV),6mm2,Black Jacket(Cores:Blue,Brown),43A,2 Equivalent Cores

Terminal

AC power chassis

Naked Crimping Terminal,OT,6mm2,M6,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow

DC power distribution cabinet

Naked Crimping Terminal,OT,6mm2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow

Cables Between the EPS200-4850B AC Power Chassis and the AC Power Distribution Cabinet

Table 1-95 lists the cables Between the AC power chassis and the EPS200-4850B AC Power Distribution cabinet.

Table 1-95  Cables between the EPS200-4850B AC power chassis and the AC power distribution cabinet

Item

Description

Power cable

External Suite, Power Cords All Over The World, Class I Equipment With Connector C19, External Cable Set

Translation
Download
Updated: 2019-01-04

Document ID: EDOC1100059253

Views: 13914

Downloads: 26

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next