HUAWEI NIP6800 Series V500 Hardware Guide

This document of the NIP6800 Series describes hardware structure, installation guide, and hardware maintenance. The content of this document includes the appearance and specifications of the product, the supported expansion cards, preparation before the installation, installation, cabling, and hardware replacement.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LPU and FPICs

LPU and FPICs

The flexible LPU comprises the motherboard and multiple flexible cards (subcards), improving networking flexibility, which reduces costs and provides customized solutions for users.

LPUF-240

The hot-swappable LPUF-240 supports 240G line-rate forwarding. It supports mixed insertion among different FPICs and has two half-width slots, each of which holds one FPIC.

The LPUF-240 does not support the hot swap of FPICs.

Mapping

Table 1-57 shows the mapping among the LPUF-240, chassis, FPIC, and software version.

Table 1-57  Mapping relationship

Board

Mapping Chassis

Mapping FPIC

Mapping Software Version

LPUF-240

NIP6860

V500R001C50 and later

Panel

Figure 1-38 shows the LPUF-240.

Figure 1-38  LPUF-240

Number

Name

Description

1

OFL button

To remove a board, press and hold the button for five seconds until the OFL indicator turns on.

2

OFL indicator (red)

Steady on: You can remove the board.

3

RUN indicator (green)

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

Technical Specifications

Table 1-58 lists the technical specifications of the LPUF-240.

Table 1-58  Technical specifications of the LPUF-240

Item

Specifications

Board silkscreen name

LPUF-240

NIP-LPUF-240

Part number

03057476

Dimensions (width x depth x height)

399.2 mm x 555.2 mm x 40.1 mm

Typical power consumption

353 W

Maximum power consumption

410 W

Typical heat consumption

1204.5 BTU/hour

Maximum heat consumption

1399 BTU/hour

Board weight

9 kg

LPUF-120

The hot-swappable LPUF-120 provides two 1/2-width slots, each of which holds one subcard. It supports 120G line-rate forwarding and mixed insertion among different FPICs.

The LPUF-120 does not support the hot swap of FPICs.

The total LPUF-120 subcard performance cannot exceed 120G. To insert the NIP-1X100G-CFP or on the LPUF-120, you can insert only one NIP-1X100G-CFP or .

Mapping

Table 1-59 shows the mapping among the LPUF-120, chassis, FPIC, and software version.

Table 1-59  Mapping relationship

Board

Mapping Chassis

Mapping FPIC

Mapping Software Version

LPUF-120

V500R001C50 and later

Panel

Figure 1-39 shows the LPUF-120.

Figure 1-39  LPUF-120

Number

Name

Description

1

OFL button

To remove a board, press and hold the button for five seconds until the OFL indicator turns on.

2

OFL indicator (red)

Steady on: You can remove the board.

3

RUN indicator (green)

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

Technical Specifications

Table 1-60 lists the technical specifications of the LPUF-120.

Table 1-60  Technical specifications of the LPUF-120

Item

Specifications

Board silkscreen name

LPUF-120

NIP-LPUF-120

Part number

03057477

Dimensions (width x depth x height)

400 mm x 530 mm x 41 mm

Typical power consumption

195 W

Maximum power consumption

214.5 W

Typical heat consumption

665.4 BTU/hour

Maximum heat consumption

731.9 BTU/hour

Board weight

7.15 kg

NIP-24XGE-SFP

The NIP-24XGE-SFP is inserted into the LPU, occupies one 1/2-width flexible card slot, and is not hot-swappable. It provides twenty-four GE optical interfaces for data access and processing.

The NIP-24XGE-SFP supports the following features:

  • GE optical module, supporting GE optical interface features.

  • FE optical module, supporting FE optical interface features.

  • Electrical SFP module, supporting 1000M electrical interface feature.

  • Mixed insertion among the above modules.

NOTE:

Only the interfaces indexed in odd numbers support the electrical interface module.

Mapping

Table 1-61 shows the mapping among the NIP-24XGE-SFP, chassis, LPU, and software version.

Table 1-61  Mapping relationship

Board

Mapping Chassis

Mapping LPU

Mapping Software Version

NIP-24XGE-SFP

V500R001C50 and later

Indicator Description

Figure 1-40 shows indicators on the NIP-24XGE-SFP.

Figure 1-40  Indicators on the NIP-24XGE-SFP

Table 1-62 describes indicators on the NIP-24XGE-SFP.

Table 1-62  Indicator description

Number

Name

Description

1

STATUS (green)

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

2

Indicator below the interface (green)

  • Steady on: The link is connected.

  • Blinking: Data is being transmitted or received.

  • Off: The link is disconnected.

Interface Description

Figure 1-41 shows interfaces on the NIP-24XGE-SFP.

Figure 1-41  Interfaces on the NIP-24XGE-SFP

1. 24 x GE optical interface

Table 1-63 lists the attributes of interfaces on the NIP-24XGE-SFP.

Table 1-63  NIP-24XGE-SFP interface attributes

Attribute

Description

Connector type

LC/PC

Optical interface attribute

Compliant with the selected SFP optical module

For details about the optional attributes of the optical module, see:

Working mode

Full duplex

Standards compliance

IEEE 802.3-2002

Frame format

Ethernet_II, Ethernet_SAP, Ethernet_SNAP, and 802.3

Network protocol

IP

Technical Specifications

Table 1-64 lists the technical specifications of the NIP-24XGE-SFP.

Table 1-64  Technical specifications of the NIP-24XGE-SFP

Item

Specifications

Board silkscreen name

NIP-24XGE-SFP

Part number

03057469

Dimensions (width x depth x height)

178 mm x 225 mm x 38 mm

Typical power consumption

37 W

Maximum power consumption

40.7 W

Typical heat consumption

126.2 BTU/hour

Maximum heat consumption

138.9 BTU/hour

Board weight

0.9 kg

NIP-6X10G-SFP+

The NIP-6X10G-SFP+ is inserted into the LPU, occupies one 1/2-width flexible card slot, and is not hot-swappable. It provides six 10GE optical interfaces for data access and processing. Interfaces on it can be configured to work in LAN or WAN mode and use the SFP+ optical transceivers.

Mapping

Table 1-65 shows the mapping among the NIP-6X10G-SFP+, chassis, LPU, and software version.

Table 1-65  Mapping relationship

Board

Mapping Chassis

Mapping LPU

Mapping Software Version

NIP-6X10G-SFP+

V500R001C50 and later

Indicator Description

Figure 1-42 shows indicators on the NIP-6X10G-SFP+.

Figure 1-42  Indicators on the NIP-6X10G-SFP+

Table 1-66 describes indicators on the NIP-6X10G-SFP+.

Table 1-66  Indicator description

Number

Name

Description

1

STA (green)

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

2

Indicator below the interface (green)

  • Steady on: The link is connected.

  • Blinking: Data is being transmitted or received.

  • Off: The link is disconnected.

Interface Description

Figure 1-43 shows interfaces on the NIP-6X10G-SFP+.

Figure 1-43  Interfaces on the NIP-6X10G-SFP+

1. 6 x 10GE optical interface

Table 1-67 lists the attributes of interfaces on the NIP-6X10G-SFP+.

Table 1-67  NIP-6X10G-SFP+ interface attributes

Attribute

Description

Connector type

LC/PC

Optical interface attribute

Compliant with the selected SFP+ optical module.

For details about the optional attributes of the optical module, see:

Working mode

Full-duplex

Frame format

Ethernet_II, Ethernet_SAP, and Ethernet_SNAP

Network protocol

IP

Technical Specifications

Table 1-68 lists the technical specifications of the NIP-6X10G-SFP+.

Table 1-68  Technical specifications of the NIP-6X10G-SFP+

Item

Specifications

Board silkscreen name

NIP-6X10G-SFP+

Part number

03057472

Dimensions (width x depth x height)

178 mm x 180 mm x 38 mm

Typical power consumption

34 W

Maximum power consumption

37.4 W

Typical heat consumption

116 BTU/hour

Maximum heat consumption

127.6 BTU/hour

Board weight

0.65 kg

NIP-12X10G-SFP+

The NIP-12X10G-SFP+ is inserted into the LPU, occupies one 1/2-width flexible card slot, and is not hot-swappable. It provides twelve 10GE optical interfaces for data access and processing. Interfaces on it can be configured to work in LAN or WAN mode and use the SFP+ optical transceivers.

Mapping

Table 1-69 shows the mapping among the NIP-12X10G-SFP+, chassis, LPU, and software version.

Table 1-69  Mapping relationship

Board

Mapping Chassis

Mapping LPU

Mapping Software Version

NIP-12X10G-SFP+

V500R001C50 and later

Indicator Description

Figure 1-44 shows indicators on the NIP-12X10G-SFP+.

Figure 1-44  Indicators on the NIP-12X10G-SFP+

Table 1-70 describes indicators on the NIP-12X10G-SFP+.

Table 1-70  Indicator description

Number

Name

Description

1

STA (green)

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

2

Indicator below the interface (green)

  • Steady on: The link is connected.

  • Blinking: Data is being transmitted or received.

  • Off: The link is disconnected.

Interface Description

Figure 1-45 shows interfaces on the NIP-12X10G-SFP+.

Figure 1-45  Interfaces on the NIP-12X10G-SFP+

1. 12 x 10GE optical interface

Table 1-71 lists the attributes of interfaces on the NIP-12X10G-SFP+.

Table 1-71  NIP-12X10G-SFP+ interface attributes

Attribute

Description

Connector type

LC/PC

Optical interface attribute

Compliant with the selected SFP+ optical module.

For details about the optional attributes of the optical module, see:

Working mode

Full-duplex

Frame format

Ethernet_II, Ethernet_SAP, and Ethernet_SNAP

Network protocol

IP

Technical Specifications

Table 1-72 lists the technical specifications of the NIP-12X10G-SFP+.

Table 1-72  Technical specifications of the NIP-12X10G-SFP+

Item

Specifications

Board silkscreen name

NIP-12X10G-SFP+

Part number

03057473

Dimensions (width x depth x height)

193 mm x 178.65 mm x 37.2 mm

Typical power consumption

52 W

Maximum power consumption

57.2 W

Typical heat consumption

177.4 BTU/hour

Maximum heat consumption

195.2 BTU/hour

Board weight

0.75 kg

NIP-1X100G-CFP

The NIP-1X100G-CFP is inserted into the LPU, occupies one 1/2-width flexible card slot, and is not hot-swappable. It provides a 100GE optical interface for data access and processing. Interfaces on it can be configured to work only in LAN mode and use CFP optical transceivers.

Mapping

Table 1-73 shows the mapping among the NIP-1X100G-CFP, chassis, LPU, and software version.

Table 1-73  Mapping relationship

Board

Mapping Chassis

Mapping LPU

Mapping Software Version

NIP-1X100G-CFP
NOTE:

When an LPUF-120 is used, only one NIP-1X100G-CFP can be installed due to bandwidth limits.

V500R001C50 and later

Indicator Description

Figure 1-46 shows indicators on the NIP-1X100G-CFP.

Figure 1-46  Indicators on the NIP-1X100G-CFP

Table 1-74 describes indicators on the NIP-1X100G-CFP.

Table 1-74  Indicator description

Indicator

Name

Color

Status

Description

STATUS

`

STATUS indicator

Green

Blinking

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

L/A

L/A indicator

Green

Steady on

The link is connected.

Green

Blinking

Data is being transmitted or received.

-

Off

The link is disconnected.

Interface Description

Figure 1-47 shows interfaces on the NIP-1X100G-CFP.

Figure 1-47  Interfaces on the NIP-1X100G-CFP

1. 1 x 100GE optical interface

Table 1-75 lists the attributes of interfaces on the NIP-1X100G-CFP.

Table 1-75  NIP-1X100G-CFP interface attributes

Attribute

Description

Connector type

LC/PC

Optical interface attribute

Compliant with the selected CFP optical module

For details about the optional attributes of the optical module, see 100 Gbit/s CFP Optical Modules.

Working mode

Full duplex

Frame format

Ethernet_II, Ethernet_SAP, and Ethernet_SNAP

Network protocol

IP

Technical Specifications

Table 1-76 lists the technical specifications of the NIP-1X100G-CFP.

Table 1-76  Technical specifications of the NIP-1X100G-CFP

Item

Specifications

Board silkscreen name

NIP-1X100G-CFP

Part number

03057470

Dimensions (width x depth x height)

178 mm x 130 mm x 35 mm

Typical power consumption

51 W

Maximum power consumption

56.1 W

Typical heat consumption

174 BTU/hour

Maximum heat consumption

191.4 BTU/hour

Board weight

1.3 kg

NIP-3X40G-QSFP+

The NIP-3X40G-QSFP+ is inserted into the LPU, occupies one 1/2-width flexible card slot, and is not hot-swappable. It provides three 40GE optical interfaces for data access and processing. Interfaces on it can be configured to work in LAN mode and use the QSFP+ optical transceivers.

Mapping

Table 1-77 shows the mapping among the NIP-3X40G-QSFP+, chassis, LPU, and software version.

Table 1-77  Mapping relationship

Board

Mapping Chassis

Mapping LPU

Mapping Software Version

NIP-3X40G-QSFP+

V500R001C50 and later

Indicator Description

Figure 1-48 shows indicators on the NIP-3X40G-QSFP+.

Figure 1-48  Indicators on the NIP-3X40G-QSFP+

Table 1-78 describes indicators on the NIP-3X40G-QSFP+.

Table 1-78  Indicator description

Indicator

Name

Color

Status

Description

STATUS

`

STATUS indicator

Green

Blinking

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

L/A

L/A indicator

Green

Steady on

The link is connected.

Green

Blinking

Data is being transmitted or received.

-

Off

The link is disconnected.

Interface Description

Figure 1-49 shows interfaces on the NIP-3X40G-QSFP+.

Figure 1-49  Interfaces on the NIP-3X40G-QSFP+

1. 3 x 40GE optical interface

Table 1-79 lists the attributes of interfaces on NIP-3X40G-QSFP+.

Table 1-79  NIP-3X40G-QSFP+ interface attributes

Attribute

Description

Connector type

LC/PC

Optical interface attributes

Compliant with the selected SFP+ optical module. For details about the optional attributes of the optical module, see 40 Gbit/s QSFP+ Optical Modules.

Working mode

Full-duplex

Standards compliance

IEEE 802.3-2002

Frame format

Ethernet_II, Ethernet_SAP, and Ethernet_SNAP

Network protocol

IP

Technical Specifications

Table 1-80 lists the technical specifications of the NIP-3X40G-QSFP+.

Table 1-80  Technical specifications of the NIP-3X40G-QSFP+

Item

Specifications

Board silkscreen name

NIP-3X40G-QSFP+

Part number

03057471

Dimensions (width x depth x height)

178 mm x 225 mm x 38 mm

Typical power consumption

50 W

Maximum power consumption

55 W

Typical heat consumption

170.6 BTU/hour

Maximum heat consumption

187.7 BTU/hour

Board weight

0.85 kg

Translation
Download
Updated: 2019-01-04

Document ID: EDOC1100059253

Views: 20423

Downloads: 45

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next