HUAWEI NIP6800 Series V500 Hardware Guide

This document of the NIP6800 Series describes hardware structure, installation guide, and hardware maintenance. The content of this document includes the appearance and specifications of the product, the supported expansion cards, preparation before the installation, installation, cabling, and hardware replacement.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SFUs

SFUs

SFUs are responsible for data switching between boards. The NIP6830 does not support SFUs.

E8KE-X8-SFUC-200

E8KE-X8-SFUC-200 is the NIP6860 SFU. It uses non-blocking switch fabric, is hot-swappable, and is responsible for data switching of the entire system.

Mapping

Table 1-37 shows the mapping among the E8KE-X8-SFUC-200, chassis, and software version.

Table 1-37  Mapping relationship

Board

Mapping Chassis

Mapping Software Version

E8KE-X8-SFUC-200

NIP6860

V500R001C50 and later

Panel

Figure 1-28 shows the E8KE-X8-SFUC-200.

Figure 1-28  E8KE-X8-SFUC-200

Number

Name

Description

1

ACT (green)

  • Steady on: The SFU is working properly.

  • Off: The SFU is faulty.

2

RUN indicator (green)

  • Blinks every 2 seconds (0.5 Hz): The system is working properly.

  • Blinks twice each second (2 Hz): The system is in the alarm state.

3

OFL button

To remove a board, press and hold the button for six seconds until the OFL indicator turns on.

4

OFL indicator (red)

Steady on: You can remove the board.

Technical Specifications

Table 1-38 lists the technical specifications of the E8KE-X8-SFUC-200.

Table 1-38  Technical specifications of the E8KE-X8-SFUC-200

Item

Specifications

Specifications

SFUI-200-C

Part number

0305G08P

Dimensions (width x depth x height)

400 mm x 553.5 mm x 35 mm

Typical power consumption

77 W

Maximum power consumption

90 W

Typical heat consumption

262.7 BTU/hour

Maximum heat consumption

307.1 BTU/hour

Board weight

3.82 kg