No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HUAWEI NIP6800 Series V500 Hardware Guide

This document of the NIP6800 Series describes hardware structure, installation guide, and hardware maintenance. The content of this document includes the appearance and specifications of the product, the supported expansion cards, preparation before the installation, installation, cabling, and hardware replacement.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EPS200-4850B AC Power Chassis

EPS200-4850B AC Power Chassis

The EPS200-4850B AC power chassis is a AC-input and DC-output power module.

Mapping

Table 1-20 describes the mapping between the EPS200-4850B AC power chassis and NIP6800 chassis.

Table 1-20  Mapping relationship

Power Module

NIP6830

NIP6860

EPS200-4850B

Not supported.

Supported only by the AC model; one power module in standard configuration.

Appearance

Figure 1-18 and Figure 1-19 show the AC power chassis.

Figure 1-18  Front view of the AC power chassis

Figure 1-19  Rear view of the AC power chassis

NOTE:

The NIP6860 does not support the AC power chassis management function. Therefore, you do not need to install the monitoring cable delivered with the auxiliary material package on the DB9 port at the rear of the AC power chassis.

Table 1-21 describes indicators on the panel of the AC power chassis.

Table 1-21  Indicator description

Indicator

Color

Normal

Abnormal

Cause

Power running indicator

Green

On

Off

Power failure (no AC input, over-voltage AC input, or under-voltage AC input) and no output from the power module

Protection indicator

Yellow

Off

On

Temperature alarm (when the ambient temperature exceeds 65°C, the device is powered off.)

Dormant (when the device is in dormant state, the protection indicator of the module is on but the module does not report alarms.)

Fault indicator

Red

Off

On

No output due to the over-voltage output power-off, fan fault, over-temperature power-off, or internal module fault.

Technical Specifications

Table 1-22 lists the technical specifications of the AC power chassis.

Table 1-22  Technical specifications of the AC power chassis

Item

Technical Specification

Model

EPS200-4850B

Part number

02312DHA

Dimensions (Width x Depth x Height)

442 mm x 650 mm x 88 mm

Number of power inputs

4

Maximum input voltage range

  • 220 V rated voltage: 175 V AC to 264 V AC, 47 Hz to 63 Hz
  • 110 V rated voltage: 90 V AC to 175 V AC, 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.)

Rated input voltage range

  • 220 V rated voltage: 200 V AC to 240 V AC, 50/60 Hz
  • 110 V rated voltage: 100 V AC to 120 V AC, 50/60 Hz

Input current

  • 220 V rated voltage: 18.5 A per module (Each power supply input with at least 18.5 A current is recommended.)
  • 110 V rated voltage: 16 A per module (Each power supply input with at least 16 A current is recommended.)

Number of power outputs

4

Maximum output current

50 A/single module

Maximum output power

2900 W/single module