ME60 V800R010C10SPC500 Feature Description - MPLS 01

This is ME60 V800R010C10SPC500 Feature Description - MPLS
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
UNI Tunnel Calculation Using Both IP and Optical PCE Servers

UNI Tunnel Calculation Using Both IP and Optical PCE Servers

Background

IP service provision on E2E backbone networks faces the following challenges:
  • Optical and IP layers cannot share topology information. Therefore, path planning can only be manually performed at both the optical and IP layers. Optimizing path calculation and network resources is difficult.
  • Inter-layer network deployment is performed by collaboration of IP and optical departments, which delays service rollout.

To face the preceding challenges, the ME60 uses both the IP Path Computation Element (PCE) and optical PCE functions to calculate paths for GMPLS UNI tunnels.

With this path calculation function, the IP and optical PCE servers automatically implement path planning, which reduces manual workload and speeds up service rollout.

Principles

An ingress EN on a GMPLS UNI functions as a PCE client and requests an IP PCE server to calculate paths. Upon receipt of the request, the IP PCE server works with an optical PCE server to calculate path and sends path information to the ingress EN. The ingress EN automatically establishes a GMPLS UNI tunnel over the calculated path.

In the following example, the IP and optical PCE servers are used simultaneously to calculate a path for a GMPLS UNI tunnel between the ingress EN and egress EN. The implementation is as follows:
  1. The ingress EN sends a delegate path request for a GMPLS UNI tunnel to an IP PCE server.
  2. Upon receipt of the request, the IP PCE server instructs the optical PCE server to calculate a path within an optical network.
  3. The optical PCE server sends path information to the IP PCE server.
  4. The IP PCE server sends all path information to the ingress EN.
  5. The ingress EN sends RSVP messages to the ingress CN and starts to establish a GMPLS UNI tunnel. The GMPLS UNI tunnel establishment process is similar to the common GMPLS UNI tunnel establishment process. The establishment procedure is not described.
Figure 6-7 Flowchart for using both the IP and optical PCE servers to calculate paths

Benefits

Simultaneously using the IP and optical PCE servers to calculate a path for a GMPLS UNI tunnel offers the following benefits:
  • Automatically performs a great amount of site deployment planning, which reduces labor costs.
  • Eliminates the collaboration between the IP and optical service departments, which speeds up site deployment.