Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Chassis

Chassis

ME60-X3

Overview

Table 7-1 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

ME60-X3 DC

Integrated DC Chassis Components(ME60-X3)

02351954

ME0B0BKPD330

V800R008C10

ME60-X3 AC

ME60-X3 Integrated AC Chassis Components, (Including Dual AC Power)

02355493

ME0B0BKPA331

V800R008C10

Appearance

Figure 7-1 Appearance (DC)

Figure 7-2 Appearance (AC)

Components

Figure 7-3 Components (front view)



1. MPU

2. BSU/MSU

3. Cable tray

4. Rack-mounting ear

5. Air intake vent

6. Handle

7. DC Power module

8. Air filter

9. Ground terminal

10. Fan

Figure 7-4 Components (rear view)



1. MPU

2. BSU/MSU

3. Cable tray

4. AC Power module

5. Rack-mounting ear

6. Air intake vent

7. Handle

8. Air filter

9. Ground terminal

10. Fan

Slot Layout

Figure 7-5 Slot layout

Table 7-2 Description of slot layout

Slot Name

Slot Quantity

Slot ID

Remarks

BSU/MSU

3

1 to 3

These slots hold BSU/MSUs.

MPU

2

4 to 5

These slots hold MPUs.

Interface Numbering

An interface is numbered in the format of slot number/card number/port number

NOTE:

Slot number: The slots of BSU/MSUs are numbered from 1 to 3. The slot number increases from bottom to top, facing the front panel of the ME60 (there are corresponding marks on the panel).

Card number: The cards of BSU/MSUs are numbered from right to left and from bottom to top beginning with 0. If there is no card on a board, the card number is set to 0.

Port number: The ports of BSU/MSUs are numbered from top to bottom and from right to left beginning with 0.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

  • DC: (4 U) 175 mm x 442 mm x 650 mm (6.89 in. x 17.40 in. x 25.59 in.)
  • AC: (5 U) 220 mm x 442 mm x 650 mm (8.66 in. x 17.40 in. x 25.59 in.)

Weight (empty)

  • DC: 12 kg (26.46 lb)
  • AC: 20 kg (44.1 lb)

Weight (full configuration)

  • DC: 42 kg (92.61 lb)
  • AC: 52 kg (114.66 lb)

Cabinet installation standard

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

  • DC: 800 W (fully configured with BSUF-51s)
  • AC: 950 W (fully configured with BSUF-51s)
  • DC: 920 W (fully configured with BSUF-100s)
  • AC: 1070 W (fully configured with BSUF-100s)

Typical heat dissipation

  • DC: 2595.5 BTU/hour (fully configured with BSUF-51s)
  • AC: 3082.2 BTU/hour (fully configured with BSUF-51s)
  • DC: 2984.9 BTU/hour (fully configured with BSUF-100s)
  • AC: 3471.5 BTU/hour (fully configured with BSUF-100s)

DC input voltage

  • input voltage range: –38.4 V to –72 V
  • input rated voltage: –48 V/ –60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

MTBF

34.76 years

MTTR

0.5 hours

Availability

0.999998358

Slot quantity

5

Redundant MPUs

1:1

Redundant Switch fabrics

N/A

Redundant fans

When a single fan fails, other fans will compensate for the loss of fan volume, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

Redundant power supply

1+1

Forwarding performance

  • 300 Mpps (BSUF-100)

Switching capacity

1.08 Tbps

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)

ME60-X8

Overview

Table 7-3 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

ME60-X8

ME60-X8 Integrated Chassis Components (Including 4 DC Power)

02352021

ME0B0BKP0830

V800R008C10

Appearance

Figure 7-6 Appearance

Components

Figure 7-7 Components (front view)

1. Air intake vent

2. SRU

3. SFU

4. BSU/MSU

5. Cable tray

Figure 7-8 Components (rear view)

6. Fan

7. Filler Panel

8. Ground terminal

9. Rear cable trough

10. Power management interface

11. DC power module

12. Handle

13. Central monitoring module (Optional)

14. Mounting ear

Slot Layout

Figure 7-9 Slot layout

Table 7-4 Description of slot layout

Slot Name

Slot Quantity

Slot ID

Remarks

BSU/MSU

8

1 to 8

These slots hold BSU/MSUs.

SRU

2

9 to 10

These slots hold SRUs.

SFU

1

11

These slots hold SFUs.

Interface Numbering

An interface is numbered in the format of Slot number/card number/Port number

NOTE:

Slot number: The slots of BSU/MSUs are numbered from 1 to 8. The slot number increases from left to right facing the front panel of the ME60 (there are corresponding marks on the panel).

Card number: The cards of BSU/MSUs are numbered from top to bottom and from right to left beginning with 0. If there is no card on a board, the card number is set to 0.

Port number: The ports of BSU/MSUs are numbered from left to right and from top to bottom beginning with 0.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

  • (14 U) 620 mm x 442 mm x 650 mm (24.41 in. x 17.40 in. x 25.59 in.)(Chassis main body)
  • (14 U) 620 mm x 442 mm x 770 mm (24.41 in. x 17.40 in. x 30.31 in.)(Dimensions of the chassis body together with cable trays and front and back attachments)

Weight (empty)

25.8 kg (56.89 lb) (without filler panels)

Weight (full configuration)

136 kg (299.88 lb)

Cabinet installation standard

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

3220 W (fully configured with BSUF-240s)

Typical heat dissipation

10447 BTU/hour (fully configured with BSUF-240s)

DC input voltage

  • input voltage range: –38.4 V to –72 V
  • input rated voltage: –48 V/ –60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

MTBF

33.89 years

MTTR

0.5 hours

Availability

0.999998316

Slot quantity

11

Redundant MPUs

1:1

Redundant Switch fabrics

2+1

Redundant fans

  • When a single fan fails, other fans will compensate for the loss of fan volume, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

Redundant power supply

2+2

Forwarding performance

1600 Mpps (BSUF-240)

Switching capacity

7.08 Tbps (BSUF-240)

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)

ME60-X8A

Overview

Table 7-5 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

ME60-X8A DC

ME60-X8A Integrated Chassis DC Components(Including 2 Fan Tray)

02350RGX

ME0B0BKP0871

V800R008C10

ME60-X8A AC

ME60-X8A Integrated Chassis AC Components(Including 2 Fan Tray)

02350RGY

ME0B0BKP0872

V800R008C10

ME60-X8A HVDC

ME60-X8A Integrated Chassis HVDC Components(Including 2 Fan Tray)

02351CCJ

ME0B0BKP0873

V800R009C10

Appearance

Figure 7-10 Appearance

Components

Figure 7-11 Components (front view)

1. Rack-mounting ear

2. ESD jack

3. Lifting handle

4. Air intake frame (With air filter)

5. BSU/MSU

6. SRU

7. SFU

8. Switch module

9. Power monitoring module (PMU)

10 Power module (PM)

11. Cabling tray

12. Power module cover

Figure 7-12 Components (rear view)

13. Fan module

14. ESD jack

15. Ground terminal

16. Power entry module (PEM)

17. Non-lifting handle

Slot Layout

Figure 7-13 Slot layout

Table 7-6 Description of slot layout

Slot Name

Slot Quantity

Slot ID

Remarks

BSU/MSU

8

1 to 8

These slots hold BSU/MSUs.

SRU

2

9 to 10

These slots hold SRUs.

SFU

2

11 to 12

These slots hold SFUs.

Interface Numbering

An interface is numbered in the format of slot number/subcard number/port number.

NOTE:

Slot number: The slots of BSU/MSUs are numbered from top to bottom and from left to right (marked on the panel), in the range of 1 to 8.

Subcard number: The subcards are numbered from top to bottom and from left to right, starting from 0. If an BSU/MSU does not have any subcard, the subcard number is 0.

Port number: The ports are numbered from top to bottom and from left to right, starting from 0.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

  • (21 U) 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body)
  • (21 U) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)

Weight (empty)

  • DC: 68.1 kg (150.16 lb) (without filler panels)
  • HVDC&AC: 63.7 kg (140.46 lb) (without filler panels)

Weight (full configuration)

  • [400G bundle] DC:186.1 kg (410.35 lb)
  • [400G bundle] HVDC&AC:184.3 kg (406.38 lb)
  • [1T bundle] DC:209 kg (460.85 lb)
  • [1T bundle]HVDC&AC:206.5 kg (455.33 lb)

Cabinet installation standard

  • Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

  • 4110 W (fully configured with BSUF-240s)
  • 4770 W (fully configured with BSUF-480s)
  • 6520 W (fully configured with SFUI-1Ts)

Typical heat dissipation

  • 13334.6 BTU/hour (fully configured with BSUF-240s)
  • 15475.9 BTU/hour (fully configured with BSUF-480s)
  • 21153.6 BTU/hour (fully configured with SFUI-1Ts)

DC input voltage

  • input voltage range: –40 V to –72 V
  • input rated voltage: –48 V/ –60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

HVDC input voltage

  • input voltage range: 192V DC to 400V DC
  • input rated voltage: 240V DC/380V DC

MTBF

36.23 years

MTTR

0.5 hours

Availability

0.999998425

Slot quantity

12

Redundant MPUs

1:1

Redundant Switch fabrics

3+1

Redundant fans

  • [400G bundle] 2 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • [1T bundle] 3 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

Redundant power supply

  • [400G bundle] DC: 3+1
  • [400G bundle] HVDC&AC: 3+3
  • [1T bundle] DC: 5+1
  • [1T bundle] HVDC&AC: 4+4

Forwarding performance

1600 Mpps (BSUF-240)

Switching capacity

  • 25.16 Tbps (SFUI-1T)

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)

ME60-X16

Overview

Table 7-7 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

ME60-X16

ME60-X16 Integrated Chassis Components (Including 8 DC Power)

02352024

ME0B0BKP1630

V800R008C10

Appearance

Figure 7-14 Appearance

Components

Figure 7-15 Components

1.Air intake frame

2. MPU

3. Front cable trough

4. SFU

5.BSU/MSU

6. Handle

7. Mounting ear

8. Fan module

9. Filler Panel

10. Power entry module (PEM)

NOTE:

A DC PEM is used as an example here.

11. Rear cable trough

12. Power management interface

13. Ground terminal

14. ESD jack (rear)

15. Central monitoring module (Optional)

Slot Layout

Figure 7-16 Slot layout

Table 7-8 Description of slot layout

Slot Name

Slot Quantity

Slot ID

Remarks

BSU/MSU

16

1 to 16

These slots hold BSU/MSUs.

MPU

2

17 to 18

These slots hold MPUs.

SFU

4

19 to 22

These slots hold SFUs.

Interface Numbering

An interface is numbered in the format of slot number/card number/port number

NOTE:

Slot number: The slots of BSU/MSUs are numbered from 1 to 16. The slot number increases from left to right and from top to bottom, facing the front panel of the ME60 (there are corresponding marks on the panel).

Card number:
  • Upper chassis
    • The cards of BSU/MSUs are numbered from top to bottom and from right to left beginning with 0. If there is no card on a board, the card number is set to 0.
  • Lower chassis
    • The cards of BSU/MSUs are numbered from bottom to top and from left to right beginning with 0. If there is no card on a board, the card number is set to 0.
Port number:
  • Upper chassis
    • The ports of BSU/MSUs are numbered from left to right and from top to bottom beginning with 0.
  • Lower chassis
    • The ports of BSU/MSUs are numbered from right to left and from bottom to top beginning with 0.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

  • (32 U) 1420 mm x 442 mm x 650 mm (55.91 in. x 17.40 in. x 25.59 in.) (Chassis main body)
  • (32 U) 1420 mm x 442 mm x 770 mm (55.91 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)

Weight (empty)

69.6 kg (153.47 lb) (without filler panels)

Weight (full configuration)

279 kg (615.2 lb)

Cabinet installation standard

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

6210 W (fully configured with BSUF-240s)

Typical heat dissipation

20147.9 BTU/hour (fully configured with BSUF-240s)

DC input voltage

  • input voltage range: –38.4 V to –72 V
  • input rated voltage: –48 V/ –60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

MTBF

34.11 years

MTTR

0.5 hours

Availability

0.999998327

Slot quantity

22

Redundant MPUs

1:1

Redundant Switch fabrics

3+1

Redundant fans

  • When a single fan fails, other fans will compensate for the loss of fan volume, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

Redundant power supply

4+4

Forwarding performance

3200 Mpps (BSUF-240)

Switching capacity

12.58 Tbps (BSUF-240)

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)

ME60-X16A

Overview

Table 7-9 Device attributes

Product Type

Description

BOM

Model

Earliest Software Version

ME60-X16A DC

ME60-X16A Integrated DC Chassis Components(Including 4 Fan Tray)

02350RHA

ME0B0BKP1671

V800R008C10

ME60-X16A AC

ME60-X16A Integrated AC Chassis Components(Including 4 Fan Tray)

02350RHB

ME0B0BKP1672

V800R008C10

ME60-X16A HVDC

ME60-X16A Integrated HVDC Chassis Components(Including 4 Fan Tray)

02351CBN

ME0B0BKP1673

V800R009C10

Appearance

Figure 7-17 Appearance

Components

Figure 7-18 Components

1. Air intake frame (Air Filter)

2. Mounting ear

3. ESD jack (front)

4. Air intake vent in the SFU area

5. Handle

6. Power module cover

7. Power module (PM)

8. Power monitoring module (PMU)

9. Switch module

10. MPU

11. Cable tray

12. Cable guide for switch and fabric units (SFUs)

13. SFU

14. BSU/MSU

15. Power entry module (PEM)
NOTE:
An AC PEM is used as an example here.The DC PEM is also supported.

16. Fan Module

17. Air filter

18. Ground terminal

19. Non-lifting handle

20. ESD jack (rear)

Slot Layout

Figure 7-19 Slot layout

Table 7-10 Description of slot layout

Slot Name

Slot Quantity

Slot ID

Remarks

BSU/MSU

16

1 to 16

These slots hold BSU/MSUs.

MPU

2

17 to 18

These slots hold MPUs.

SFU

4

19 to 22

These slots hold SFUs.

Technical Specifications

Item

Specification

Dimensions (H x W x D)

  • (40 U) 1778 mm x 442 mm x 650 mm (70.00 in. x 17.40 in. x 25.59 in.) (Chassis main body)
  • (40 U) 1778 mm x 442 mm x 750 mm (70.00 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)

Weight (empty)

  • DC: 120.5 kg (265.7 lb) (without filler panels)
  • HVDC&AC: 111.7 kg (246.3 lb) (without filler panels)

Weight (full configuration)

  • [400G bundle] DC:356 kg (784.98 lb)
  • [400G bundle] HVDC&AC:350.7 kg (773.29 lb)
  • [1T bundle] DC:399.4 kg (880.68 lb)
  • [1T bundle] HVDC&AC:395.1 kg (871.2 lb)

Cabinet installation standard

  • Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

  • 7720 W (fully configured with BSUF-240s)
  • 9040 W (fully configured with BSUF-480s)
  • 12390 W (fully configured with SFUI-1Ts)

Typical heat dissipation

  • 25046.9 BTU/hour (fully configured with BSUF-240s)
  • 29329.6 BTU/hour (fully configured with BSUF-480s)
  • 40198.4 BTU/hour (fully configured with SFUI-1Ts)

DC input voltage

  • input voltage range: –40 V to –72 V
  • input rated voltage: -48 V/–60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

HVDC input voltage

  • input voltage range: 192V DC to 400V DC
  • input rated voltage: 240V DC/380V DC

MTBF

36.39 years

MTTR

0.5 hours

Availability

0.999998431

Slot quantity

22

Redundant MPUs

1:1

Redundant Switch fabrics

3+1

Redundant fans

  • [400G bundle] 4 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • [1T bundle] 6 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

Redundant power supply

  • [400G bundle] DC: 6+1
  • [400G bundle] HVDC&AC: 5+5
  • [1T bundle] DC: 9+1
  • [1T bundle] HVDC&AC: 7+7

Forwarding performance

3200 Mpps (BSUF-240)

Switching capacity

  • 50.32 Tbps (SFUI-1T)

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +50°C (23°F to 122°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)