No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

ME60 V800R010C10SPC500 Hardware Description

This is ME60 V800R010C10SPC500 Hardware Description
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

Item

ME60-X3

ME60-X8

ME60-X16

ME60-X8A

ME60-X16A

Dimensions (H x W x D)

  • DC: (4 U) 175 mm x 442 mm x 650 mm (6.89 in. x 17.40 in. x 25.59 in.)
  • AC: (5 U) 220 mm x 442 mm x 650 mm (8.66 in. x 17.40 in. x 25.59 in.)
  • (14 U) 620 mm x 442 mm x 650 mm (24.41 in. x 17.40 in. x 25.59 in.)(Chassis main body)
  • (14 U) 620 mm x 442 mm x 770 mm (24.41 in. x 17.40 in. x 30.31 in.)(Dimensions of the chassis body together with cable trays and front and back attachments)
  • (32 U) 1420 mm x 442 mm x 650 mm (55.91 in. x 17.40 in. x 25.59 in.) (Chassis main body)
  • (32 U) 1420 mm x 442 mm x 770 mm (55.91 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
  • (21 U) 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body)
  • (21 U) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
  • (40 U) 1778 mm x 442 mm x 650 mm (70.00 in. x 17.40 in. x 25.59 in.) (Chassis main body)
  • (40 U) 1778 mm x 442 mm x 750 mm (70.00 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)

Weight (empty)

  • DC: 12 kg (26.46 lb)
  • AC: 20 kg (44.1 lb)

25.8 kg (56.89 lb) (without filler panels)

69.6 kg (153.47 lb) (without filler panels)

  • DC: 68.1 kg (150.16 lb) (without filler panels)
  • HVDC&AC: 63.7 kg (140.46 lb) (without filler panels)
  • DC: 120.5 kg (265.7 lb) (without filler panels)
  • HVDC&AC: 111.7 kg (246.3 lb) (without filler panels)

Weight (full configuration)

  • DC: 42 kg (92.61 lb)
  • AC: 52 kg (114.66 lb)

136 kg (299.88 lb)

279 kg (615.2 lb)

  • [400G bundle] DC:186.1 kg (410.35 lb)
  • [400G bundle] HVDC&AC:184.3 kg (406.38 lb)
  • [1T bundle] DC:209 kg (460.85 lb)
  • [1T bundle]HVDC&AC:206.5 kg (455.33 lb)
  • [400G bundle] DC:356 kg (784.98 lb)
  • [400G bundle] HVDC&AC:350.7 kg (773.29 lb)
  • [1T bundle] DC:399.4 kg (880.68 lb)
  • [1T bundle] HVDC&AC:395.1 kg (871.2 lb)

Cabinet installation standard

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

  • Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
  • Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

  • DC: 800 W (fully configured with BSUF-51s)
  • AC: 950 W (fully configured with BSUF-51s)
  • DC: 920 W (fully configured with BSUF-100s)
  • AC: 1070 W (fully configured with BSUF-100s)

3220 W (fully configured with BSUF-240s)

6210 W (fully configured with BSUF-240s)

  • 4110 W (fully configured with BSUF-240s)
  • 4770 W (fully configured with BSUF-480s)
  • 6520 W (fully configured with SFUI-1Ts)
  • 7720 W (fully configured with BSUF-240s)
  • 9040 W (fully configured with BSUF-480s)
  • 12390 W (fully configured with SFUI-1Ts)

Typical heat dissipation

  • DC: 2595.5 BTU/hour (fully configured with BSUF-51s)
  • AC: 3082.2 BTU/hour (fully configured with BSUF-51s)
  • DC: 2984.9 BTU/hour (fully configured with BSUF-100s)
  • AC: 3471.5 BTU/hour (fully configured with BSUF-100s)

10447 BTU/hour (fully configured with BSUF-240s)

20147.9 BTU/hour (fully configured with BSUF-240s)

  • 13334.6 BTU/hour (fully configured with BSUF-240s)
  • 15475.9 BTU/hour (fully configured with BSUF-480s)
  • 21153.6 BTU/hour (fully configured with SFUI-1Ts)
  • 25046.9 BTU/hour (fully configured with BSUF-240s)
  • 29329.6 BTU/hour (fully configured with BSUF-480s)
  • 40198.4 BTU/hour (fully configured with SFUI-1Ts)

DC input voltage

  • input voltage range: –38.4 V to –72 V
  • input rated voltage: –48 V/ –60 V
  • input voltage range: –38.4 V to –72 V
  • input rated voltage: –48 V/ –60 V
  • input voltage range: –38.4 V to –72 V
  • input rated voltage: –48 V/ –60 V
  • input voltage range: –40 V to –72 V
  • input rated voltage: –48 V/ –60 V
  • input voltage range: –40 V to –72 V
  • input rated voltage: -48 V/–60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V
  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V
  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V
  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V
  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

HVDC input voltage

  • input voltage range: 192V DC to 400V DC
  • input rated voltage: 240V DC/380V DC
  • input voltage range: 192V DC to 400V DC
  • input rated voltage: 240V DC/380V DC

MTBF

34.76 years

33.89 years

34.11 years

36.23 years

36.39 years

MTTR

0.5 hours

0.5 hours

0.5 hours

0.5 hours

0.5 hours

Availability

0.999998358

0.999998316

0.999998327

0.999998425

0.999998431

Slot quantity

5

11

22

12

22

Redundant MPUs

1:1

1:1

1:1

1:1

1:1

Redundant Switch fabrics

N/A

2+1

3+1

3+1

3+1

Redundant fans

When a single fan fails, other fans will compensate for the loss of fan volume, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

  • When a single fan fails, other fans will compensate for the loss of fan volume, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • When a single fan fails, other fans will compensate for the loss of fan volume, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • [400G bundle] 2 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • [1T bundle] 3 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • [400G bundle] 4 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).
  • [1T bundle] 6 assemblies. When a single fan fails, other fans will compensate for the loss of fan volume. When a single assemblie fails, the heat dissipation system supports work for a short period of time at an ambient temperature of 40°C (104°F).

Redundant power supply

1+1

2+2

4+4

  • [400G bundle] DC: 3+1
  • [400G bundle] HVDC&AC: 3+3
  • [1T bundle] DC: 5+1
  • [1T bundle] HVDC&AC: 4+4
  • [400G bundle] DC: 6+1
  • [400G bundle] HVDC&AC: 5+5
  • [1T bundle] DC: 9+1
  • [1T bundle] HVDC&AC: 7+7

Forwarding performance

  • 300 Mpps (BSUF-100)

1600 Mpps (BSUF-240)

3200 Mpps (BSUF-240)

1600 Mpps (BSUF-240)

3200 Mpps (BSUF-240)

Switching capacity

1.08 Tbps

7.08 Tbps (BSUF-240)

12.58 Tbps (BSUF-240)

  • 25.16 Tbps (SFUI-1T)
  • 50.32 Tbps (SFUI-1T)

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)
  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)
  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)
  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)
  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +50°C (23°F to 122°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

–40°C to +70°C (–40°F to +158°F)

–40°C to +70°C (–40°F to +158°F)

–40°C to +70°C (–40°F to +158°F)

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing
  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing
  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing
  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing
  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

5% to 95% RH, non-condensing

5% to 95% RH, non-condensing

5% to 95% RH, non-condensing

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)

Less than 5000 m (16404 ft.)

Less than 5000 m (16404 ft.)

Less than 5000 m (16404 ft.)

Less than 5000 m (16404 ft.)

NOTE:
  1. In the physical dimensions shown in the table, the width (W) does not include the rack-mounting ears.
  2. Temperature and humidity are measured at 1.5 m (4.92 ft.) above the floor and 0.4 m (1.31 ft.) in front of the cabinet. There should be no protection board on the front or back of the cabinet.
  3. "Short-term" refers to continuous working time that does not exceed 96 hours and accumulated working time per year that does not exceed 15 days. If the working time exceeds either of these values, it is considered "long-term".
  4. The Bundle values in "Weight (full configuration)" include the weight of the interface boards in full configuration.
Translation
Download
Updated: 2019-01-04

Document ID: EDOC1100059474

Views: 25479

Downloads: 63

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next