ME60 V800R010C10SPC500 Hardware Description

This is ME60 V800R010C10SPC500 Hardware Description
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Heat Dissipation System of the ME60-X8

Heat Dissipation System of the ME60-X8

System Air Channel

The ME60-X8 supports two fan modules. Each fan module consists of one fan.

The ME60-X8 draws in air from the front and exhausts air from the rear. The air intake vent is located above the board area on the front chassis; the air exhaust vent is located above the board area on the rear chassis.

The two fan modules of the ME60-X8 are located side by side on the air exhaust vent, with each module containing one fan. The entire system dissipates heat by drawing in air, as shown in Figure 9-6.

Figure 9-6 Air flow in the ME60-X8

Fan Speed Adjustment

When the system is fully configured, temperatures reported by the temperature sensors on the Interface boards, SFUs, and MPUs serve as the basis for fan speed adjustment. Table 9-6 lists general principles.

Table 9-6 Fan Speed Adjustment Principles
Ambient Temperature Rotational Speed Noise and Dissipation Standards
-5°C - +27°C (23°F - 80.6°F) Low speed (50%) When fans rotate at a constantly low speed, the noises meet the standard and the fans meet heat dissipation requirements of a fully configured system.
27°C - 40°C (80.6°F - 104°F) Linear variation The fan speed is adjusted smoothly in linear mode, without a sharp increase in noises.
Over 40°C (104°F) High speed (100%) Fans rotate at high speed to meet heat dissipation requirements.

Fan Module

The fan modules, each containing one fan, are located side by side at the air exhaust vent.

Overview

Table 9-7 Fan attributes

Attribute

Description

Description

Fan Box

BOM

02120562

Model

CR5M000FBX60

Table 9-8 Mapping products and versions

Product

Earliest Software Version

X8

V800R008C10

X16

V800R008C10

Appearance



Indicators

Table 9-9 Description of indicators on the fan module

Item

Status Description

STATUS

Green

If the indicator blinks, the fan module is working properly.

Red

If the indicator blinks, the fan module or PEM fails.

Technical Specifications

Table 9-10 Technical specifications

Item

Specification

Dimensions (H x W x D)

270.7 mm x 212.2 mm x 105 mm (10.65 in. x 8.35 in. x 4.13 in.)

Weight

3.3kg (7.27 lb)

Fan quantity

1

Power consumption

55°C Ambient temperature: 200W

25°C Ambient temperature: 30W

Noise

Meets the NEBS requirements (<78dBA @ 27 °C)

Air Filter

The ME60-X8 draws in air from the front top and exhausts air from the rear top. There is a 3 U space in the upper part of the chassis and an air filter on the front of the chassis. To maximize air intake, the filter is fully perforated. The air filter is fixed to the chassis by a fastener to facilitate filter removal and replacement. Figure 9-7 shows the appearance of an air filter.

Figure 9-7 An air filter

NOTE:

Placing a black sponge air filter on the air intake vent helps to prevent dust from entering the system. Cleaning the air filter once every three months is recommended.