ME60 V800R010C10SPC500 Hardware Description

This is ME60 V800R010C10SPC500 Hardware Description
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Heat Dissipation System of the ME60-X16A

Heat Dissipation System of the ME60-X16A

System Air Channel

The ME60-X16A supports a maximum of six fan modules. For a platform with forwarding capacity as 400 Gbit/s or below. Each fan module consists of six fans.

Figure 9-14 shows the locations of the fan module and the air intake vent.

Figure 9-14 Locations of the fan module and the air channel

1. Upper air intake vent 2. Lower air intake vent 3. Air intake vent in the SFU area 4. Fan module

The ME60-X16A provides three air channels. Each of the upper board cage and the lower board cage has an air channel. Both air channels draw air from the front and exhausts air from the rear. The SFU slot area has an air channel. The air channel draws air from the left and exhausts air from the rear top and rear bottom. The system draws air for heat dissipation. Figure 9-15 shows air flows.

Figure 9-15 Diagram of air flows

Fan Speed Adjustment

This section describes the fan Speed adjustment.

When the fan tray assembly of a 1T or lower device rotates at its full speed, the maximum power of the fan tray assembly is 500 W.

When the system is in full configuration, the temperatures reported by the temperature sensors on the LPUs, SFUs, and MPUs serve as the basis for fan speed adjustment.

The 1T or lower device complies with the following principles.

Ambient Temperature Rotational Speed Noise and Dissipation Standards
-5°C - +27°C (23°F - 80.6°F) Low rotation speed (35%) When fans rotate at a constantly low speed and the fans meet heat dissipation requirements of a fully configured system.
27°C - 45°C (80.6°F - 113°F) Linear variation The fan speed is adjusted smoothly in linear mode, without a sharp increase in noises.
Over 45°C (113°F) High speed (100%) Fans rotate at high speed to meet heat dissipation requirements.

Fan Module

The fan module is located on the air exhaust vent.

Overview

Table 9-20 Fan attributes

Attribute

Description

Description

Fan Box

BOM

02120866

Model

E000FBX08

Table 9-21 Mapping products and versions

Product

Earliest Software Version

X8A

V800R008C10

X16A

V800R008C10

Appearance



Indicators

Table 9-22 Description of indicators on the fan module

Item

Status Description

STATUS

Green:

  • If the indicator blinks once every two seconds (0.5 Hz), the fan module is working properly.
  • If the indicator blinks four times every second (4 Hz), the fan module is registering.

Red:

  • If the indicator blinks once every two seconds (0.5 Hz), the fan module is faulty.

Orange:

  • If the indicator is steady on, the fan module is faulty.

Technical Specifications

Table 9-23 Technical specifications

Item

Specification

Dimensions (H x W x D)

131 mm x 440 mm x 120 mm (5.16 in. x 17.32 in. x 4.72 in.)

Weight

5.4 kg (11.90 lb)

Fan quantity

6

Power consumption

55°C Ambient temperature: 500W

25°C Ambient temperature: 48W

Noise

Meets the NEBS requirements (<78dBA @ 27 °C)

Air Filter

A black sponge air filter on the air intake vent prevents dust from getting into the system. The air filter can be removed and cleaned. Cleaning air filters once every three months is recommended.

The ME60-X16A has three air filters, the locations of which are shown in Figure 9-16.

Figure 9-16 Location of air filters

1. Upper air filter 2. Lower air filter 3. Air filter in the SFU area

The appearance of the air filter is shown in Figure 9-17.

Figure 9-17 Appearance of the air filter




Upper air filter

Lower air filter

The appearance of the air filter in the SFU slot area is shown in Figure 9-18.

Figure 9-18 Appearance of the air filter in the SFU slot area