Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Heat Dissipation System of the ME60-X8A

Heat Dissipation System of the ME60-X8A

System Air Channel

The ME60-X8A supports a maximum of three fan modules. For a platform with forwarding capacity as 400 Gbit/s or below, only two fan modules need to be configured. For a platform with forwarding capacity as 1 Tbit/s, three fan modules need to be configured. Each fan module consists of six fans.

Figure 9-8 shows the locations of the fan module and air intake vent on the ME60-X8A.

Figure 9-8 Air channel on the ME60-X8A

1. Air intake vent

2. Fan module

The system draws air from the front and discharges air from the back. The air intake vent resides above the board area on the front chassis; the air exhaust vent resides above the board area on the rear chassis. The system draws air for heat dissipation. Figure 9-9 shows air flows.

The air filters on the air intake vents are vertically installed and featured with the curved face, large area, and small windage resistance, helping to improve the heat dissipation efficiency.

Figure 9-9 Diagram of air flows

Fan Speed Adjustment

When the system is configured to the largest capacity, the fan rotation speeds are adjusted based on the temperatures reported by the sensors on the SRUs, Interface boards, and SFUs.

The 1T or lower device complies with the following principles.

Ambient Temperature Rotational Speed Noise/Heat Control
Below 27°C (75.2°F) Low rotation speed (35%) When the ambient temperature is below 27°C (75.2°F), fans rotate at a fixed low speed, which meets the noise requirement and the heat dissipation requirement.
27°C-40°C (75.2°F-104°F) Linear speed adjustment When the ambient temperature is between 27°C (75.2°F) and 40°C (104°F), the fan rotation speeds are adjusted smoothly in linear mode, and the fan noise does not change violently.
Above 40°C (104°F) High rotation speed (100%) When the ambient temperature is above 45°C (104°F), fans rotate at a fixed high speed, which meets heat dissipation requirements.

Fan Module

The fan module is located on the air exhaust vent.

Overview

Table 9-11 Fan attributes

Attribute

Description

Description

Fan Box

BOM

02120866

Model

E000FBX08

Table 9-12 Mapping products and versions

Product

Earliest Software Version

X8A

V800R008C10

X16A

V800R008C10

Appearance



Indicators

Table 9-13 Description of indicators on the fan module

Item

Status Description

STATUS

Green:

  • If the indicator blinks once every two seconds (0.5 Hz), the fan module is working properly.
  • If the indicator blinks four times every second (4 Hz), the fan module is registering.

Red:

  • If the indicator blinks once every two seconds (0.5 Hz), the fan module is faulty.

Orange:

  • If the indicator is steady on, the fan module is faulty.

Technical Specifications

Table 9-14 Technical specifications

Item

Specification

Dimensions (H x W x D)

131 mm x 440 mm x 120 mm (5.16 in. x 17.32 in. x 4.72 in.)

Weight

5.4 kg (11.90 lb)

Fan quantity

6

Power consumption

55°C Ambient temperature: 500W

25°C Ambient temperature: 48W

Noise

Meets the NEBS requirements (<78dBA @ 27 °C)

Air filter

Figure 9-10 Shows the appearance of the air filter.

Figure 9-10 Air filter

NOTE:

The black sponge air filteron the air intake vent is used to prevent dust from getting into the system. Cleaning the air filter once every three months is recommended.