Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
1009015 UNS ITA Northbound Interface Authentication Is Fail

1009015 UNS ITA Northbound Interface Authentication Is Fail

Description

When the interconnection between UNS and ITA is configured, the ITA northbound interface account password entered in the ITA list is incorrect. As a result, UNS failed to communicate with ITA, and data cannot be synchronized. Additional information on the alarm contains the IP address of the ITA. Configure the correct password in the ITA list is required. The alarm needs to be manually cleared after the settings are correctly configured.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1009015

Major

No

Parameters

Name

Meaning

Alarm ID

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Alarm Severity

Indicates the severity of an alarm. Value:

  • Critical: indicates that a fault affecting services provided by the system occurs. You need to rectify the fault immediately. If a device or resource is faulty, rectify it immediately even if the fault occurs during non-working hours.
  • Major: indicates that a fault affecting the service quality of the system occurs. You need to rectify the fault immediately. If the service quality of a device or resource is degraded, rectify it immediately during working hours.
  • Minor: indicates a fault that does not affect service quality. To prevent more serious faults, this type of alarm needs to be observed or handled if necessary.
  • Warning: indicates a fault that may affect service quality. This type of alarm must be handled based on the error type.

Alarm Name

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Object Type

Specifies the type of the object for which the alarm is generated.

Alarm Object Name

Specifies the name of the object for which the alarm is generated.

Generation Time

Specifies the time when the alarm is generated.

Clear Time

Specifies the time when the alarm is cleared.

Clear Mode

Specifies whether the alarm is manually or automatically cleared.

Operation

Specifies the operation that can be performed on the alarm.

Value: Manually Clear Alarm

Impact on the System

After you submit an account and password on the UNS login page, the corresponding VM cannot be found on the VM list page.

Possible Causes

When the interconnection between UNS and ITA is configured, the password of the ITA northbound interface account is incorrect.

Procedure

  1. Obtain the correct ITA northbound interface login information. Log in to the ITA interconnecting with the UNS, choose FusionAccess > System > Rights Management > User Management, locate the ITA northbound interface account, obtain the username and password set for unlocking the user. If you forget the password, click Reset Password to reset the ITA northbound interface password.
  2. Modify the account information obtained in the previous step to reset the password in the ITA interconnecting with UNS. Choose FusionAccess > System > Desktop Components, locate UNS Information, click the UNS cluster to which the ITA belongs, locate the ITA in ITA List, configure the correct ITA communication account and password, and click OK.
  3. After correct ITA northbound interface information is configured, choose FusionAccess > Alarm to manually clear the error message "UNS ITA Northbound Interface Authentication Is Fail".