Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
1009010 UNS Service Memory Usage Exceeds the Threshold

1009010 UNS Service Memory Usage Exceeds the Threshold

Description

By default, after UNS service startup, a service memory usage data is sent to the ITA every 2 minutes. This alarm is generated when the ITA detects that the UNS service memory usage exceeds the threshold (90% by default) for three consecutive times. This alarm is cleared when the ITA detects that the UNS service memory usage is less than the threshold.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1009010

Major

Yes

Parameters

Name

Meaning

Alarm ID

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Alarm Severity

Indicates the severity of an alarm. Value:

  • Critical: indicates that a fault affecting services provided by the system occurs. You need to rectify the fault immediately. If a device or resource is faulty, rectify it immediately even if the fault occurs during non-working hours.
  • Major: indicates that a fault affecting the service quality of the system occurs. You need to rectify the fault immediately. If the service quality of a device or resource is degraded, rectify it immediately during working hours.
  • Minor: indicates a fault that does not affect service quality. To prevent more serious faults, this type of alarm needs to be observed or handled if necessary.
  • Warning: indicates a fault that may affect service quality. This type of alarm must be handled based on the error type.

Alarm Name

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Object Type

Specifies the type of the object for which the alarm is generated.

Alarm Object Name

Specifies the name of the object for which the alarm is generated.

Generation Time

Specifies the time when the alarm is generated.

Clear Time

Specifies the time when the alarm is cleared.

Clear Mode

Specifies whether the alarm is manually or automatically cleared.

Operation

Specifies the operation that can be performed on the alarm.

Value: Manually Clear Alarm

Impact on the System

The UNS service is affected and may become abnormal when UNS service memory usage exceeds 90%.

Possible Causes

  • System resources are insufficient, and too many services exist.

Procedure

  1. Log in to a server as user root and run reboot while the service is not affected.
  2. Wait for 10 minutes and choose FusionAccess > Alarm to check whether the alarm exist.

    • If yes, contact Huawei technical support.