Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
1009014 UNS WI Cluster Name Is Incorrect

1009014 UNS WI Cluster Name Is Incorrect

Description

When the interconnection between UNS and ITA is configured, the WI cluster names entered in the ITA list must be the same as those configured in ITA. If the WI cluster names configured in ITA do not exist in the UNS configuration, no desktop is available when you log in to UNS. The alarm needs to be manually cleared after the settings are correctly configured.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1009014

Major

No

Parameters

Name

Meaning

Alarm ID

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Alarm Severity

Indicates the severity of an alarm. Value:

  • Critical: indicates that a fault affecting services provided by the system occurs. You need to rectify the fault immediately. If a device or resource is faulty, rectify it immediately even if the fault occurs during non-working hours.
  • Major: indicates that a fault affecting the service quality of the system occurs. You need to rectify the fault immediately. If the service quality of a device or resource is degraded, rectify it immediately during working hours.
  • Minor: indicates a fault that does not affect service quality. To prevent more serious faults, this type of alarm needs to be observed or handled if necessary.
  • Warning: indicates a fault that may affect service quality. This type of alarm must be handled based on the error type.

Alarm Name

Identifies an alarm. Each alarm is uniquely identified by an alarm ID and an alarm name.

Object Type

Specifies the type of the object for which the alarm is generated.

Alarm Object Name

Specifies the name of the object for which the alarm is generated.

Generation Time

Specifies the time when the alarm is generated.

Clear Time

Specifies the time when the alarm is cleared.

Clear Mode

Specifies whether the alarm is manually or automatically cleared.

Operation

Specifies the operation that can be performed on the alarm.

Value: Manually Clear Alarm

Impact on the System

After you submit an account and password on the UNS login page, the corresponding VM cannot be found on the VM list page.

Possible Causes

When the interconnection between UNS and ITA is configured, the WI cluster name is incorrectly configured in the ITA list.

Procedure

  1. Obtain the correct WI cluster name. Log in to the ITA where the incorrect WI cluster name is configured based on the alarm, and choose FusionAccess > System > Desktop Components > WI Information to locate the correct WI cluster name. Multiple WI clusters may be configured in one ITA.
  2. Correctly configure the WI cluster name in UNS based on the preceding step. Choose FusionAccess > System > Desktop Components, locate UNS Information, and open the ITA in ITA List. In the displayed WI List dialog box, enter the correct WI name and delete the WI clusters that do not exist. Pay attention to the mapping between multiple ITAs and WI clusters. After the modification is successful, click OK.
  3. After the correct WI cluster name is configured, choose FusionAccess > Alarm to manually clear the error message "UNS WI Cluster Name Is Incorrect".