Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-70402 Residual ECS Snapshot

ALM-70402 Residual ECS Snapshot

Description

This alarm is generated when the system audit detects a residual ECS snapshot.

Attribute

Alarm ID

Alarm Severity

Auto Clear

70402

Minor

Yes

Parameters

Name

Meaning

Fault Location Info

  • Service: specifies the service for which the alarm is generated.
  • MicroService: specifies the microservice for which the alarm is generated.

Additional Info

  • Service: specifies the service for which the alarm is generated.
  • MicroService: specifies the microservice for which the alarm is generated.
  • detail_info: provides detailed information about the alarm.

Impact on the System

The image file of the ECS snapshot in the residual state occupies the space of the storage system.

Possible Causes

  • The user deletes the VM corresponding to the ECS snapshot from the background.
  • Other unknown errors cause the ECS snapshot to reside.

Procedure

  1. Determine the deployment scenario of the current environment. Obtain the audit report.

  2. Determine the scenario where the current environment is deployed. Process the residual ECS snapshots by performing operations provided in section "Processing Residual ECS Snapshots."

  3. Determine the scenario where the current environment is deployed and obtain section "Manual Audit." Start the system audit again.

    • For Region Type I (cascading system), see Manual Audit.
    • Region Type II and Region Type III scenarios:

  4. On Service OM, choose Services > Service OM > Centralized O&M > Alarm > Alarm List. Check whether this alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Contact technical support for assistance.

Related Information

None