Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-1005006 Failed to back up the database

ALM-1005006 Failed to back up the database

Description

This alarm is generated when the ADS database fails to be backed up.

Attribute

Alarm ID

Alarm Severity

Auto Clear

1005006

Minor

Yes

Parameters

Name

Meaning

DATABASE

Database backup status

Impact on the System

Data cannot be restored to the state at the backup time point if the database is faulty.

Possible Causes

  1. The database backup tool is not deployed.
  2. The backup tool fails to run.
  3. The network is abnormal.
  4. The username or password of SFTP service is incorrect.
  5. The SFTP storage space is insufficient.

Procedure

  1. Use SFTP to connect to the SFTP server and check whether the database connection is normal.
  2. Check whether the database backup tool is deployed. For details, see Operation and Maintenance > Backup and Restoration > Backing Up Data > Backing Up Big Data Services in HUAWEI CLOUD Stack 6.5.0 Product Documentation.
  3. Check whether the backup tool successfully runs. For details, see Operation and Maintenance > Backup and Restoration > Backing Up Data > Backing Up Big Data Services in HUAWEI CLOUD Stack 6.5.0 Product Documentation.
  4. Check whether the SFTP connection is normal.
  5. Check whether the SFTP username or password is correct.
  6. If the preceding check results are normal but the alarm persists, contact technical support for assistance.

Alarm Clearing

After the fault is rectified, the system will automatically clear the alarm.

Reference

None

Translation