No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HUAWEI CLOUD Stack 6.5.0 Alarm and Event Reference 04

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-513 Failed to Create Volume

ALM-513 Failed to Create Volume

Description

This alarm is reported when automatic volume creation fails.

Attribute

Alarm ID

Alarm Severity

Alarm Type

513

Major

Environmental alarm

Parameters

Parameter Name

Parameter Description

kind

Resource type.

namespace

Name of the project to which the resource belongs.

name

Resource name.

uid

Unique ID of the resource.

OriginalEventTime

Event generation time.

EventSource

Name of the component that reports an event.

EventMessage

Supplementary information about an event.

Impact on the System

Applications cannot use volumes and data in the volumes. As a result, applications cannot be accessed.

System Actions

None

Possible Causes

The storage function is abnormal.

Procedure

  1. Use PuTTY to log in to the manage_lb1_ip node.

    The default username is paas, and the default password is QAZ2wsx@123!.

  2. Run the following command and enter the password of the root user to switch to the root user:

    su - root

    Default password: QAZ2wsx@123!

  3. Obtain the podname and namespace from the Location Info field in the alarm information. Run the following command to check the kubelet log and analyze the cause based on the log:

    kubectl describe pod resource name -n namespaces

    • Yes: Go to 4.
    • No: Go to 7.

  4. Check whether storage configurations are correct.

    Run the following command to obtain the configured storage parameters:

    kubectl edit configmap csms-storagemgr -n fst-manage

    Obtain the password corresponding to the user name in displayed and run the curl command:

    curl -i -k -d '{ "auth":{ "identity":{ "methods":[ "password" ],

    "password":{ "user":{ "domain":{ "name":"paas-test2" },

    "name":"paas_test2_admin", "password":"Huawei12#$" } } },

    "scope":{ "project":{ "name":"STD_sa-fb-1_paas_test2_ project",

    "domain":{ "name":"paas-test2" } } } } }' -H "Content-type: application/json" https://172.31.33.32:31943/v3/auth/tokens?nocatalog,

    Information similar to the following is displayed:

    HTTP/1.1 201 Created
    Server: product only
    Date: Thu, 28 Feb 2019 12:28:05 GMT
    Content-Type: application/json
    Transfer-Encoding: chunked
    Connection: keep-alive
    ....
    • Yes: Go to 5.
    • No: Go to 7.

  5. Use a browser to log in to the FusionStage OM zone console.

    1. Log in to ManageOne Maintenance Portal.
      • Login address: https://Address for accessing the homepage of ManageOne Maintenance Portal:31943, for example, https://oc.type.com:31943.
      • The default username is admin, and the default password is Huawei12#$.
    2. On the O&M Maps page, click the FusionStage link under Quick Links to go to the FusionStage OM zone console.

  6. Choose Project Management > Resource > Storage to check whether the storage function of the PVC works unexpectedly.

    • Yes: Go to 7.
    • No: Go to 8.

  7. Contact storage personnel to rectify the fault and then check whether the alarm is cleared.

    • Yes: No further action is required.
    • No: Go to 8.

  8. Contact technical support for assistance.

Alarm Clearing

This alarm must be manually cleared after the fault is rectified.

Related Information

None

Translation
Download
Updated: 2019-08-30

Document ID: EDOC1100062365

Views: 33537

Downloads: 31

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share