Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-999999994 License Resource Item Reaching or Exceeding the Threshold

ALM-999999994 License Resource Item Reaching or Exceeding the Threshold

Description

This alarm is generated when the system detects that usage of a license resource item has reached or exceeded the threshold; this alarm is automatically cleared when the system detects that usage of the license resource item drops below the threshold.

NOTE:

For the thresholds for generating alarms related to license resources, see the license control information. For details, see Step2.

Attribute

Alarm ID

Alarm Severity

Alarm Type

999999994

Major

Security service or mechanism violation

Parameters

Name

Meaning

ResourceID

The ID of resource items.

Impact on the System

After the alarm is generated and if it is not handled in a timely manner, you cannot access license resources when the license usage reaches the threshold. For example if the number of NEs connected to the FusionStage OM zone has reached the threshold 1000000 of license resources, you cannot connect new NEs.

Possible Causes

A license resource reaches or exceeds the threshold.

Procedure

  1. In the current alarm list, view Additional text in the alarm information to determine which license resource item is overused.
  2. Check whether usage of the license resource item has reached or exceeded the threshold.

    1. Use a browser to log in to the FusionStage OM zone console.
      1. Log in to ManageOne Maintenance Portal.
        • Login address: https://Address for accessing the homepage of ManageOne Maintenance Portal:31943, for example, https://oc.type.com:31943.
        • The default username is admin, and the default password is Huawei12#$.
      2. On the O&M Maps page, click the FusionStage link under Quick Links to go to the FusionStage OM zone console.
    2. Choose > License Management from the main menu.
    3. In the Resource Control area of the License Management page, check whether usage of the license resource item has reached or exceeded the threshold.

  3. Clear the alarm by applying for a new license file or reducing the usage of the license resource item.

    • Apply for a new license file.

      Perform 2 and 3 in ALM-999999992 License Will Expire. Then go to Step4.

    • Reduce the usage of the license resource item.

      Perform the following steps to reduce the usage of the license resource.

      Delete managed nodes one by one until usage of the license resource item drops below the threshold. Deleting a node could cause applications and services on the node to become abnormal or be terminated. Therefore, exercise caution when deleting nodes.

      1. Use a browser to log in to the FusionStage OM zone console.
        1. Log in to ManageOne Maintenance Portal.
          • Login address: https://Address for accessing the homepage of ManageOne Maintenance Portal:31943, for example, https://oc.type.com:31943.
          • The default username is admin, and the default password is Huawei12#$.
        2. On the O&M Maps page, click the FusionStage link under Quick Links to go to the FusionStage OM zone console.
      2. Choose Project Management > Resource > Node from the main menu.
      3. On the node list, select the node to be deleted, and click Delete.
      4. Enter delete and click OK.

        Exercise caution when deleting a node, because applications and services on the node will be terminated or become abnormal.

        NOTE:
        • If the node to be deleted does not exist, clicking Delete could lead to an error message. Ignore the error message and forcibly delete it.
        • If deleting a node fails, click Force Delete. The node is then deleted, but management programs and service programs on the node are not deleted. You need to manually delete these programs.

  4. Wait 60 minutes. Check whether the alarm is cleared.

    • If yes, the alarm handling process is complete.
    • If no, collect the information about alarm handling and contact the technical support personnel.

Clearing

When the fault is eliminated, the system will auto-clear the alarm. Manual clearing is not required.